FireCADCalc

ESP Collection Efficiency and Area (Deutsch–Anderson)

Collection efficiency of an electrostatic precipitator from its plate area, gas flow and migration velocity, and the area for a target efficiency.

Thermal power plantSugar mill and cogenerationChemical and fertiliserPulp and paperBoilerStack and chimneyDust collector (ESP, bag filter, cyclone)

Inputs

Examples: ESP 60 m³/s, w 0.08 m/s, 4 000 m²Bagasse ESP 35 m³/s, w 0.06 m/s, target 99.5 %Small ESP 10 m³/s, w 0.1 m/s, 500 m²

Depends on the dust's resistivity and particle size; take it from the ESP maker or from tests on a similar plant.
Any basis (actual, normal, dry or wet); the outlet value comes out on the same basis. Only the ratio is used.

Results

Collection efficiency98.624%
Dust at the ESP outlet110.11mg/Nm³
Plate area for the target efficiency3,090.7m²
Specific collecting area A/Q71.429m²/(m³/s)
Penetration1.3764%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: ESP 60 m³/s, w 0.08 m/s, 4 000 m². The inputs, in the units selected above:

InputValue
Gas flow through the ESP (actual)216,000 m³/h
Effective migration velocity0.080000 m/s
Collecting plate area4,000.0 m²
Target efficiency (for the area required)99.500 %
Dust at the ESP inlet40,000 mg/Nm³

Applying the formula below gives:

ResultValue
Collection efficiency99.517 %
Dust at the ESP outlet193.12 mg/Nm³
Plate area for the target efficiency3,973.7 m²
Specific collecting area A/Q66.667 m²/(m³/s)
Penetration0.48279 %

Open this example in the calculator and change any input.

Formula

\(\eta = 1 - e^{-w A / Q} \qquad A_{req} = -\frac{Q\,\ln(1 - \eta_t)}{w} \qquad SCA = \frac{A}{Q} \qquad c_{out} = c_{in}(1 - \eta)\)

Variables

Symbol Meaning SI unit
\(Q\) gas flow through the ESP, actual m³/s
\(w\) effective migration velocity m/s
\(A\) collecting plate area m²
\(\eta_t\) target efficiency –
\(c_{in}\) dust at the ESP inlet kg/m³
\(\eta\) collection efficiency –
\(c_{out}\) dust at the ESP outlet kg/m³
\(A_{req}\) plate area for the target efficiency m²
\(SCA\) specific collecting area s/m
\(1 - \eta\) penetration –

Method and standards

The Deutsch–Anderson equation for the collection efficiency of an electrostatic precipitator, with an effective migration velocity that lumps the electrical and particle properties (Deutsch 1922; White, Industrial Electrostatic Precipitation, 1963).

Where it is used

  • Sizing ESP collecting area.
  • Estimating efficiency after a coal change.
  • Planning ESP upgrades.

Common mistakes

  • Using a migration velocity from another dust.
  • Ignoring gas flow distribution.
  • Forgetting sneakage and rapping losses.

Assumptions and limits

  • Effective migration velocity from experience; the equation itself does not predict it.
  • Uniform gas distribution and no re-entrainment or sneakage; real ESPs fall short of the ideal at very high efficiencies.
  • The outlet concentration is on the same basis (dry or wet, reference conditions) as the inlet value; the mg/Nm³ unit shown is only a label for that basis.
  • A note appears above 99.9 %, where real ESPs fall short of the ideal.
  • SCA is shown in s/m (m² per m³/s) in every unit system; for ft² per 1000 acfm multiply by 5.08.

References

  • Deutsch (1922); Anderson; White
  • Industrial Electrostatic Precipitation (1963)

Questions and answers

How efficient is an ESP?

η = 1 − exp(−w·A/Q). With 4 000 m² of plates, 60 m³/s of gas and a migration velocity of 0.08 m/s the efficiency is 99.52 %, so 40 g/Nm³ at the inlet leaves 193 mg/Nm³.

Where does the migration velocity come from?

From the ESP maker or from tests on a similar plant and dust. It depends strongly on the dust's resistivity and particle size, which is why high-ash Indian coals need large ESPs.

How much area for 99.5 %?

A = −Q·ln(1 − η)/w. For 60 m³/s at 0.08 m/s that is 3 974 m².

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.