FireCADCalc

Centrifugal Impeller Slip (Wiesner, Pfleiderer) and Euler Head

Outlet velocity triangle of a centrifugal pump impeller, slip by Wiesner and by Pfleiderer, and the theoretical Euler head with and without slip.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 300 mm, 7 blades at 20 deg, 1,480 rpm, voluteBoiler feed stage 330 mm, 7 blades at 25 deg, 2,980 rpm, diffuserSmall 160 mm, 5 blades at 30 deg, 2,900 rpm, vaneless

Accepted: 0.02 to 3 m
Accepted: 0.1 to 0.9
Accepted: 0.001 to 0.5 m
Accepted: 95.493 to 9,549.3 rpm
Accepted: 0.036 to 72,000 m³/h
Accepted: 5.7296 to 89.994 °
Accepted: 2 to 20
Accepted: 30 to 100 %

Results

No pre-swirl at the inlet. Blade blockage at the outlet is ignored, which slightly underestimates the meridional velocity. regards Pfleiderer's method as the more rational for real pumps; Wiesner's is a fit to Busemann's theory.

Tip speed24.295m/s
Meridional (radial) velocity1.4921m/s
Whirl without slip21.711m/s
Wiesner slip, V_s/U_20.22920
Pfleiderer slip coefficient0.61538
Euler head without slip53.786m
Euler head with Wiesner slip39.991m
Euler head with Pfleiderer slip33.296m
Pump head (Wiesner × hydraulic efficiency)31.993m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 300 mm, 7 blades at 20 deg, 1,480 rpm, volute. The inputs, in the units selected above:

InputValue
Impeller outlet diameter0.30000 m
Inlet (eye) to outlet radius ratio0.40000 -
Outlet width0.020000 m
Speed1,480.0 rpm
Flow through the impeller180.00 m³/h
Outlet blade angle (from tangential)20.000 °
Number of blades7.0000 -
Pfleiderer collector factorVolute, 0.8
Hydraulic efficiency85.000 %

Applying the formula below gives:

ResultValue
Tip speed23.248 m/s
Meridional (radial) velocity2.6526 m/s
Whirl without slip15.960 m/s
Wiesner slip, V_s/U_20.14978
Pfleiderer slip coefficient0.36518
Euler head without slip37.835 m
Euler head with Wiesner slip29.580 m
Euler head with Pfleiderer slip27.714 m
Pump head (Wiesner × hydraulic efficiency)25.143 m

Open this example in the calculator and change any input.

Formula

\(U_2 = \frac{\omega D_2}{2}, \quad V_{m2} = \frac{Q}{\pi D_2b_2}, \quad V_{\theta2,\infty} = U_2 - \frac{V_{m2}}{\tan\beta_{b2}}\)

\(\frac{V_s}{U_2} = \frac{\sqrt{\sin\beta_{b2}}}{n_b^{0.7}}, \quad p = \frac{a(1 + \sin\beta_{b2})\,r_2^2}{n_b\,(r_2^2 - r_1^2)/2}, \quad H = \frac{U_2V_{\theta2}}{g}\)

Variables

Symbol Meaning SI unit
\(D_2\) Impeller outlet diameter m
\(r_1/r_2\) Inlet (eye) to outlet radius ratio -
\(b_2\) Outlet width m
\(n\) Speed rad/s
\(Q\) Flow through the impeller m³/s
\(\beta_{b2}\) Outlet blade angle (from tangential) rad
\(n_b\) Number of blades -
\(a\) Pfleiderer collector factor -
\(\eta_h\) Hydraulic efficiency -
\(U_2\) Tip speed m/s
\(V_{m2}\) Meridional (radial) velocity m/s
\(V_{\theta2,\infty}\) Whirl without slip m/s
\(\sigma_W\) Wiesner slip, V_s/U_2 -
\(p\) Pfleiderer slip coefficient -
\(H_\infty\) Euler head without slip m
\(H_{th,W}\) Euler head with Wiesner slip m
\(H_{th,P}\) Euler head with Pfleiderer slip m
\(H\) Pump head (Wiesner × hydraulic efficiency) m

Method and standards

Euler turbomachine equation with Wiesner and Pfleiderer slip.

Where it is used

  • Preliminary impeller design.
  • Estimating the effect of trimming or blade count.

Common mistakes

  • Measuring the blade angle from the radial direction.
  • Treating the Euler head as the delivered head.

Assumptions and limits

  • Radial impeller, no inlet swirl, outlet blockage ignored.

Questions and answers

Why does slip reduce the head?

With a finite number of blades the flow leaves the impeller at a flatter angle than the blades, so the outlet whirl and therefore the Euler head are lower.

What do the defaults represent?

A 300 mm, seven-blade impeller with 20° blades and a 20 mm outlet at 1,480 rpm passing 0.05 m³/s into a volute: tip speed 23.2 m/s, Wiesner slip 0.150, Euler head 37.8 m without slip and 29.6 m with it.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008), sec. 2.1.1, eqs. 15 and 52 and Table 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.