Steam Main Warm-Up and Running Condensate Load

Condensate formed while warming a steam main from cold in a set time and during running from heat loss, with the drain trap load including a safety factor.

Thermal power plantProcess steam and utilitiesRefinery and petrochemical

Inputs

Examples: Illustrative DN100, 50 m, 10 bar(a), 20 minDN250 main 80 m at 41 bar(a)Small DN50 line 30 m at 4 bar(a)

Accepted: 0.5 to 2,000 kg/m
Accepted: 1 to 500 m
Accepted: 1.1 to 200 bar
Accepted: -43.15 to 126.85 °C
Accepted: 0.3 to 0.6 kJ/(kg·K)
Accepted: 1 to 600 min
Accepted: 1 to 2,000 W/m
Accepted: 1 to 5

Results

Warm-up: steel heated from T₀ to saturation by condensing steam, m = m'Lc(T_s − T₀)/h_fg (IAPWS-IF97), averaged over the warm-up time; insulation and heat loss during warm-up add a little. Running: heat loss/h_fg. Size drain traps for the larger with a safety factor, and at low start-up pressure.

Steam saturation temperature143.61°C
Latent heat2,133.3kJ/kg
Warm-up condensate5.1577kg
Warm-up condensate rate30.946kg/h
Running condensate rate1.7719kg/h
Trap capacity needed92.838kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative DN100, 50 m, 10 bar(a), 20 min. The inputs, in the units selected above:

InputValue
Pipe mass per metre (with flanges)17.000 kg/m
Length between drain points50.000 m
Steam pressure (absolute)11.000 bar
Initial pipe temperature10.000 °C
Pipe specific heat0.49000 kJ/(kg·K)
Warm-up time20.000 min
Running heat loss per metre60.000 W/m
Trap safety factor2.0000 -

Applying the formula below gives:

ResultValue
Steam saturation temperature184.07 °C
Latent heat1,999.5 kJ/kg
Warm-up condensate36.260 kg
Warm-up condensate rate108.78 kg/h
Running condensate rate5.4014 kg/h
Trap capacity needed217.56 kg/h

Open this example in the calculator and change any input.

Formula

\(m_w = \frac{m'Lc(T_s - T_0)}{h_{fg}}, \quad \dot m_r = \frac{q'L}{h_{fg}}, \quad \dot m_{trap} = k_s\max(\dot m_w/t_w, \dot m_r)\)

Variables

Symbol Meaning SI unit
\(m'\) Pipe mass per metre (with flanges) kg/m
\(L\) Length between drain points m
\(p\) Steam pressure (absolute) Pa
\(T_0\) Initial pipe temperature K
\(c\) Pipe specific heat J/(kg·K)
\(t_w\) Warm-up time s
\(q'\) Running heat loss per metre W/m
\(k_s\) Trap safety factor -
\(T_s\) Steam saturation temperature K
\(h_{fg}\) Latent heat J/kg
\(m_w\) Warm-up condensate kg
\(\dot m_w\) Warm-up condensate rate kg/s
\(\dot m_r\) Running condensate rate kg/s
\(\dot m_{trap}\) Trap capacity needed kg/s

Method and standards

Warm-up load.

Where it is used

  • Steam main drain trap selection.
  • Start-up procedures.

Common mistakes

  • Sizing traps for running load only.
  • Using full pressure for start-up trap capacity.

Assumptions and limits

  • Uniform pipe; steel heated to saturation.

References

  • Warm-up and running condensate loads

Questions and answers

Why is warm-up load larger than running load?

Heating tonnes of cold steel to steam temperature in minutes condenses far more steam than steady heat loss does.

Why drain every 30–50 m?

Condensate collecting in long mains causes water hammer; regular drain pockets with traps remove it.

What do the defaults represent?

An illustrative 50 m run of DN100 Sch 40 pipe (about 17 kg/m with flanges) warmed to 10 bar(a) steam from 10 °C in 20 minutes, 60 W/m running loss.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Spirax-Sarco, The Steam and Condensate Loop (Spirax-Sarco)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.