Insulation Thickness for Personnel Protection (Surface Temperature)

Insulation thickness that keeps the outer surface of a hot pipe at or below a safe touch temperature, with the heat loss at that thickness.

Process steam and utilities

Inputs

Examples: Illustrative 4 in pipe at 250 CThermic fluid line at 300 CLarge duct at 400 C

Accepted: 5 to 3,000 mm
Accepted: 26.85 to 826.85 °C
Accepted: -40 to 60 °C
Accepted: 26.85 to 100 °C
Accepted: 0.01 to 0.5 W/(m·K)
Accepted: 2 to 50 W/(m²·K)

Results

Heat flows out through the insulation (resistance ln(r₂/r₁)/(2πk) per metre) and from the surface to the air (1/(2πr₂h)). The surface temperature is ambient plus the heat flow times the surface resistance; the thickness is found by bisection so that it equals the safe limit, commonly 60 °C for metal jacketing and slightly higher for non-metallic surfaces. Bright metal jacketing radiates little, so its surface coefficient is lower and it runs hotter: use a lower h for it.

Insulation thickness needed52.160mm
Surface temperature at that thickness60.000°C
Heat loss per metre97.123W/m
Outer diameter of insulation193.22mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 4 in pipe at 250 C. The inputs, in the units selected above:

InputValue
Pipe outside diameter114.30 mm
Pipe (process) temperature250.00 °C
Ambient temperature35.000 °C
Highest safe surface temperature60.000 °C
Insulation thermal conductivity at mean temperature0.045000 W/(m·K)
Outer surface coefficient (convection plus radiation)9.0000 W/(m²·K)

Applying the formula below gives:

ResultValue
Insulation thickness needed30.860 mm
Surface temperature at that thickness60.000 °C
Heat loss per metre124.42 W/m
Outer diameter of insulation176.02 mm

Open this example in the calculator and change any input.

Formula

\(q = \frac{T_i - T_a}{\dfrac{\ln(r_2/r_1)}{2\pi k} + \dfrac{1}{2\pi r_2 h_s}}, \quad T_s = T_a + \frac{q}{2\pi r_2 h_s} \le T_{max}\)

Variables

Symbol Meaning SI unit
\(D\) Pipe outside diameter m
\(T_i\) Pipe (process) temperature K
\(T_a\) Ambient temperature K
\(T_{max}\) Highest safe surface temperature K
\(k\) Insulation thermal conductivity at mean temperature W/(m·K)
\(h_s\) Outer surface coefficient (convection plus radiation) W/(m²·K)
\(t\) Insulation thickness needed m
\(T_s\) Surface temperature at that thickness K
\(q\) Heat loss per metre W/m
\(D_o\) Outer diameter of insulation m

Method and standards

Personnel protection.

Where it is used

  • Hot pipes and equipment in walkways.
  • Safety audits of steam and thermic fluid lines.

Common mistakes

  • Using the same surface coefficient for bright jacketing.
  • Ignoring sun on outdoor pipes.

Assumptions and limits

  • Steady state; uniform conductivity.

References

  • Radial conduction with a surface coefficient
  • thickness by bisection

Questions and answers

How much insulation keeps a 250 °C, 4 in pipe below 60 °C?

About 31 mm of mineral wool (k = 0.045) with h = 9 W/(m²·K).

Is personnel-protection thickness enough for energy saving?

Usually not: economic thickness is often two or three times greater.

What do the defaults represent?

An illustrative 4 in (114.3 mm) pipe at 250 °C in 35 °C air, insulation k 0.045 W/(m·K), surface coefficient 9 W/(m²·K), limit 60 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.