Worked example
Example: Illustrative 4 in pipe at 250 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pipe outside diameter | 114.30 mm |
| Pipe (process) temperature | 250.00 °C |
| Ambient temperature | 35.000 °C |
| Highest safe surface temperature | 60.000 °C |
| Insulation thermal conductivity at mean temperature | 0.045000 W/(m·K) |
| Outer surface coefficient (convection plus radiation) | 9.0000 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Insulation thickness needed | 30.860 mm |
| Surface temperature at that thickness | 60.000 °C |
| Heat loss per metre | 124.42 W/m |
| Outer diameter of insulation | 176.02 mm |
Open this example in the calculator and change any input.
Formula
\(q = \frac{T_i - T_a}{\dfrac{\ln(r_2/r_1)}{2\pi k} + \dfrac{1}{2\pi r_2 h_s}}, \quad T_s = T_a + \frac{q}{2\pi r_2 h_s} \le T_{max}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Pipe outside diameter | m |
| \(T_i\) | Pipe (process) temperature | K |
| \(T_a\) | Ambient temperature | K |
| \(T_{max}\) | Highest safe surface temperature | K |
| \(k\) | Insulation thermal conductivity at mean temperature | W/(m·K) |
| \(h_s\) | Outer surface coefficient (convection plus radiation) | W/(m²·K) |
| \(t\) | Insulation thickness needed | m |
| \(T_s\) | Surface temperature at that thickness | K |
| \(q\) | Heat loss per metre | W/m |
| \(D_o\) | Outer diameter of insulation | m |
Method and standards
Personnel protection.
Where it is used
- Hot pipes and equipment in walkways.
- Safety audits of steam and thermic fluid lines.
Common mistakes
- Using the same surface coefficient for bright jacketing.
- Ignoring sun on outdoor pipes.
Assumptions and limits
- Steady state; uniform conductivity.
References
- Radial conduction with a surface coefficient
- thickness by bisection
Questions and answers
How much insulation keeps a 250 °C, 4 in pipe below 60 °C?
About 31 mm of mineral wool (k = 0.045) with h = 9 W/(m²·K).
Is personnel-protection thickness enough for energy saving?
Usually not: economic thickness is often two or three times greater.
What do the defaults represent?
An illustrative 4 in (114.3 mm) pipe at 250 °C in 35 °C air, insulation k 0.045 W/(m·K), surface coefficient 9 W/(m²·K), limit 60 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.