Pressure Rise in Blocked-In Liquid-Full Pipe on Heating

Pressure rise per kelvin and for a temperature rise in a closed, liquid-full thin-walled pipe, from liquid expansion and compressibility and pipe elasticity.

Thermal power plantProcess steam and utilitiesRefinery and petrochemical

Inputs

Examples: Illustrative water 20 C, 200 mm steel, 10 KWarm water 50 C, 5 KHydrocarbon in 50 mm tube

Accepted: 1E-5 to 0.003 1/K
Accepted: 0.01 to 10 1/GPa
Accepted: 1E-6 to 3E-5 1/K
Accepted: 5 to 2,000 mm
Accepted: 0.5 to 100 mm
Accepted: 1 to 300 GPa
Accepted: 0.1 to 0.5
Accepted: 0.1 to 200 K

Results

Volume balance: (β − 3α)ΔT = (κ + C_p)Δp, with C_p = D(5/4 − ν)/(Et) the volumetric strain per pressure of a closed thin cylinder. Water's β rises steeply with temperature; even a few kelvin can overpressure blocked-in lines, hence thermal relief valves.

Pipe pressure compliance0.0791671/GPa
Pressure rise per kelvin of heating8.0780bar
Pressure rise40.390bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative water 20 C, 200 mm steel, 10 K. The inputs, in the units selected above:

InputValue
Liquid volumetric expansion coefficient2.0700e-04 1/K
Liquid compressibility0.45900 1/GPa
Pipe linear expansion coefficient1.2000e-05 1/K
Pipe mean diameter200.00 mm
Wall thickness8.0000 mm
Pipe elastic modulus200.00 GPa
Poisson's ratio0.30000 -
Temperature rise10.000 K

Applying the formula below gives:

ResultValue
Pipe pressure compliance0.11875 1/GPa
Pressure rise per kelvin of heating2.9598 bar
Pressure rise29.598 bar

Open this example in the calculator and change any input.

Formula

\(\frac{dp}{dT} = \frac{\beta - 3\alpha}{\kappa + \frac{D}{Et}\left(\frac54 - \nu\right)}\)

Variables

Symbol Meaning SI unit
\(\beta\) Liquid volumetric expansion coefficient 1/K
\(\kappa\) Liquid compressibility 1/Pa
\(\alpha\) Pipe linear expansion coefficient 1/K
\(D\) Pipe mean diameter m
\(t\) Wall thickness m
\(E\) Pipe elastic modulus Pa
\(\nu\) Poisson's ratio -
\(\Delta T\) Temperature rise K
\(C_p\) Pipe pressure compliance 1/Pa
\(dp/dT\) Pressure rise per kelvin of heating Pa
\(\Delta p\) Pressure rise Pa

Method and standards

Trapped-liquid pressure.

Where it is used

  • Thermal relief valve justification.
  • Hydrotest pressure-temperature correction.

Common mistakes

  • Using water β at the wrong temperature.
  • Ignoring pipe compliance for thin pipes.

Assumptions and limits

  • Closed, thin-walled, unrestrained pipe; elastic.

References

  • Volume balance of a closed liquid-full thin cylinder

Questions and answers

Why does trapped liquid build so much pressure?

Liquids are nearly incompressible, so a small expansion that the pipe cannot accommodate raises pressure by tens of bar.

Why does hydrotest pressure drift with sunshine?

Warming of the test water raises pressure by this mechanism; cooling lowers it and can be mistaken for a leak.

What do the defaults represent?

Illustrative water at 20 °C (β 2.07 × 10⁻⁴ /K, κ 0.459 /GPa) in a 200 mm, 8 mm wall steel pipe warmed by 10 K.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Young and Budynas, Roark's Formulas for Stress and Strain, 7th ed. (McGraw-Hill, 2002)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.