FireCADCalc

Bellows Expansion Joint Pressure Thrust and Anchor Load

Effective area and pressure thrust of an unrestrained bellows expansion joint, its spring force for a displacement and the total main anchor load.

Inputs

Examples: Illustrative DN300 bellows at 10 barDN100 steam line at 16 barDN800 low-pressure gas duct

Accepted: 0 to 1,000 bar
Accepted: 5 to 10,000 mm
Accepted: 6 to 10,000 mm
Accepted: 0.001 to 10,000,000 N/mm
Accepted: 0 to 1,000 mm

Results

An unrestrained bellows cannot carry the pressure end load of the pipe, so the pressure acting on its effective area, about the area of the mean corrugation diameter, must be taken by main anchors: F_p = p·πD_m²/4. Add the bellows spring force k_a·x for the movement absorbed (and friction of guides, not included). The thrust can be many times the pipe's weight, which is why tied, hinged or pressure-balanced joints are used where anchors are impractical. Use the maker's effective area where available.

Mean diameter340.00mm
Effective area907.92cm²
Pressure thrust90.792kN
Spring force15.000kN
Main anchor load105.79kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative DN300 bellows at 10 bar. The inputs, in the units selected above:

InputValue
Design pressure (gauge)10.000 bar
Bellows inside diameter (corrugation root)310.00 mm
Bellows outside diameter (corrugation crest)370.00 mm
Axial spring rate600.00 N/mm
Axial movement taken up25.000 mm

Applying the formula below gives:

ResultValue
Mean diameter340.00 mm
Effective area907.92 cm²
Pressure thrust90.792 kN
Spring force15.000 kN
Main anchor load105.79 kN

Open this example in the calculator and change any input.

Formula

\(A_e = \frac\pi4\left(\frac{D_i + D_o}{2}\right)^2, \quad F_a = pA_e + k_ax\)

Variables

Symbol Meaning SI unit
\(p\) Design pressure (gauge) Pa
\(D_i\) Bellows inside diameter (corrugation root) m
\(D_o\) Bellows outside diameter (corrugation crest) m
\(k_a\) Axial spring rate N/m
\(x\) Axial movement taken up m
\(D_m\) Mean diameter m
\(A_e\) Effective area m²
\(F_p\) Pressure thrust N
\(F_s\) Spring force N
\(F_a\) Main anchor load N

Method and standards

Bellows thrust.

Where it is used

  • Anchor design for steam, hot water and gas lines.
  • Choosing expansion joint type.

Common mistakes

  • Using the pipe bore area.
  • Using test pressure for operating anchors (and vice versa).

Assumptions and limits

  • Unrestrained axial bellows; static pressure; guides frictionless.

References

  • Pressure thrust of unrestrained bellows
  • Expansion Joint Manufacturers Association
  • Standards of the EJMA
  • 10th ed. (method: effective area from mean diameter)

Questions and answers

Why is the anchor load so large?

The full pressure acts on the bellows' effective area, which is larger than the pipe bore.

How can pressure thrust be avoided?

With tied, hinged, gimbal or pressure-balanced expansion joints, which contain it internally.

What do the defaults represent?

An illustrative DN300 bellows (310 to 370 mm corrugations) at 10 bar, 600 N/mm spring rate, taking 25 mm of movement.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.