Worked example
Example: Illustrative DN300 bellows at 10 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Design pressure (gauge) | 10.000 bar |
| Bellows inside diameter (corrugation root) | 310.00 mm |
| Bellows outside diameter (corrugation crest) | 370.00 mm |
| Axial spring rate | 600.00 N/mm |
| Axial movement taken up | 25.000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mean diameter | 340.00 mm |
| Effective area | 907.92 cm² |
| Pressure thrust | 90.792 kN |
| Spring force | 15.000 kN |
| Main anchor load | 105.79 kN |
Open this example in the calculator and change any input.
Formula
\(A_e = \frac\pi4\left(\frac{D_i + D_o}{2}\right)^2, \quad F_a = pA_e + k_ax\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Design pressure (gauge) | Pa |
| \(D_i\) | Bellows inside diameter (corrugation root) | m |
| \(D_o\) | Bellows outside diameter (corrugation crest) | m |
| \(k_a\) | Axial spring rate | N/m |
| \(x\) | Axial movement taken up | m |
| \(D_m\) | Mean diameter | m |
| \(A_e\) | Effective area | m² |
| \(F_p\) | Pressure thrust | N |
| \(F_s\) | Spring force | N |
| \(F_a\) | Main anchor load | N |
Method and standards
Bellows thrust.
Where it is used
- Anchor design for steam, hot water and gas lines.
- Choosing expansion joint type.
Common mistakes
- Using the pipe bore area.
- Using test pressure for operating anchors (and vice versa).
Assumptions and limits
- Unrestrained axial bellows; static pressure; guides frictionless.
References
- Pressure thrust of unrestrained bellows
- Expansion Joint Manufacturers Association
- Standards of the EJMA
- 10th ed. (method: effective area from mean diameter)
Questions and answers
Why is the anchor load so large?
The full pressure acts on the bellows' effective area, which is larger than the pipe bore.
How can pressure thrust be avoided?
With tied, hinged, gimbal or pressure-balanced expansion joints, which contain it internally.
What do the defaults represent?
An illustrative DN300 bellows (310 to 370 mm corrugations) at 10 bar, 600 N/mm spring rate, taking 25 mm of movement.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.