Worked example
Example: 3 m level difference, 2 m crest, 50 mm, K 6. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Level difference between the two surfaces | 3.0000 m |
| Height of the crest above the upper surface | 2.0000 m |
| Pipe inside diameter | 50.000 mm |
| Loss coefficient: entry, bends and friction f L/d, without the exit | 6.0000 - |
| Loss coefficient from the inlet to the crest | 2.0000 - |
| Liquid density | 998.00 kg/m³ |
| Vapour pressure of the liquid | 0.023390 bar |
| Atmospheric pressure | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Velocity in the pipe | 2.8993 m/s |
| Flow | 20.494 m³/h |
| Absolute pressure at the crest | 0.69168 bar |
| Highest crest before the pressure reaches vapour pressure | 8.8283 m |
Open this example in the calculator and change any input.
Formula
\(v = \sqrt{\frac{2 g H}{1 + K_t}}, \quad p_c = p_a - \rho g z_c - (1 + K_c)\frac{\rho v^2}{2}\)
\(Q = v\frac{\pi d^2}{4}, \quad z_{max} = \frac{p_a - p_v - (1 + K_c)\rho v^2/2}{\rho g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Level difference between the two surfaces | m |
| \(z_c\) | Height of the crest above the upper surface | m |
| \(d\) | Pipe inside diameter | m |
| \(K_t\) | Loss coefficient: entry, bends and friction f L/d, without the exit | - |
| \(K_c\) | Loss coefficient from the inlet to the crest | - |
| \(\rho\) | Liquid density | kg/m³ |
| \(p_v\) | Vapour pressure of the liquid | Pa |
| \(p_a\) | Atmospheric pressure | Pa |
| \(v\) | Velocity in the pipe | m/s |
| \(Q\) | Flow | m³/s |
| \(p_c\) | Absolute pressure at the crest | Pa |
| \(z_{max}\) | Highest crest before the pressure reaches vapour pressure | m |
| \(g\) | Standard gravity, 9.806 65 | m/s² |
Method and standards
Bernoulli with losses.
Where it is used
- Draining tanks and pits.
- Cooling water and condensate siphons.
Common mistakes
- Ignoring vapour pressure.
- Counting the exit loss twice: it is the 1 in (1 + K_t), so K_t excludes it.
Assumptions and limits
- Steady, full-bore flow.
- K_t covers entry, bends and friction; the exit loss (one velocity head) is already in the formula as the 1.
- When the crest pressure would fall below the vapour pressure the siphon breaks: flow, velocity and crest pressure are not shown.
References
- Bernoulli with losses between the surfaces and to the crest (Textbook fluid mechanics (White, Fluid Mechanics))
Questions and answers
3 m level difference, 50 mm pipe, total K = 6?
Velocity 2.90 m/s, 20.5 m³/h.
How high can the crest be?
Below about 10 m for cold water, less with flow losses and warm water.
Why does warm water break a siphon?
Its vapour pressure is higher, so it boils at the crest sooner.