FireCADCalc

Open Channel Critical Depth, Specific Energy and Froude Number

Critical depth, critical velocity and minimum specific energy of a rectangular channel, with the Froude number and specific energy at a given depth.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 3 m³/s in a 2 m channel, 0.5 m deepDrain: 0.2 m³/s, 0.6 m wide, 0.4 m deepRiver: 50 m³/s, 10 m, 2 m

Results

Subcritical (tranquil) flow: Fr < 1.

Critical depth (q²/g)^{1/3}0.22460m
Critical velocity1.4841m/s
Minimum specific energy 1.5 y_c0.33690m
Specific energy at the actual depth0.43541m
Froude number at the actual depth0.42075

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 m³/s in a 2 m channel, 0.5 m deep. The inputs, in the units selected above:

InputValue
Flow10,800 m³/h
Channel width2.0000 m
Actual depth0.50000 m

Applying the formula below gives:

ResultValue
Critical depth (q²/g)^{1/3}0.61219 m
Critical velocity2.4502 m/s
Minimum specific energy 1.5 y_c0.91829 m
Specific energy at the actual depth0.95887 m
Froude number at the actual depth1.3548

Open this example in the calculator and change any input.

Formula

\(y_c = \left(\frac{q^2}{g}\right)^{1/3}, \quad E = y + \frac{v^2}{2g}, \quad Fr = \frac{v}{\sqrt{g y}}\)

Variables

Symbol Meaning SI unit
\(Q\) Flow m³/s
\(b\) Channel width m
\(y\) Actual depth m
\(y_c\) Critical depth (q²/g)^{1/3} m
\(v_c\) Critical velocity m/s
\(E_{min}\) Minimum specific energy 1.5 y_c m
\(E\) Specific energy at the actual depth m
\(Fr\) Froude number at the actual depth -

Method and standards

Rectangular channel hydraulics.

Where it is used

  • Drains, flumes and spillways.
  • Hydraulics examinations.

Common mistakes

  • Total flow instead of flow per metre width.
  • Non-rectangular sections.

Assumptions and limits

  • Rectangular channel, uniform velocity.

References

  • Open-channel hydraulics (Chow, Open-Channel Hydraulics)

Questions and answers

3 m³/s in a 2 m channel?

Critical depth 0.612 m; at 0.5 m depth Fr 1.35 (supercritical).

What does critical depth mean?

The depth of minimum specific energy for the flow, where Fr = 1.

Where does it occur?

At free overfalls, weir crests and changes of slope.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.