FireCADCalc

Minor Losses in Fittings and Valves (K Method)

Pressure drop and head loss through pipe fittings and valves from the sum of their K values and the velocity, with the equivalent pipe length for a friction factor.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 50 m³/h in 4-inch pipe, ΣK 6.5Oil 20 m³/h in 2-inch, ΣK 12Air 0.5 m³/s in 300 mm, ΣK 3

From the fitting maker or a published table for each bend, tee and valve; add them up.

Results

Velocity7.0736m/s
Velocity head2.5511m
Head loss Σ K v²/2g7.6532m
Pressure drop0.090063kPa
Equivalent pipe length Σ K d/f52.941m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 m³/h in 4-inch pipe, ΣK 6.5. The inputs, in the units selected above:

InputValue
Volume flow50.000 m³/h
Pipe inside diameter102.30 mm
Sum of the K values of the fittings6.5000 -
Fluid density998.00 kg/m³
Darcy friction factor of the pipe (for the equivalent length)0.019000 -

Applying the formula below gives:

ResultValue
Velocity1.6898 m/s
Velocity head0.14558 m
Head loss Σ K v²/2g0.94627 m
Pressure drop9.2612 kPa
Equivalent pipe length Σ K d/f34.997 m

Open this example in the calculator and change any input.

Formula

\(h_L = \sum K\, \frac{v^2}{2g}, \quad \Delta p = \sum K\, \frac{\rho v^2}{2}, \quad L_e = \frac{\sum K\, d}{f}\)

Variables

Symbol Meaning SI unit
\(Q\) Volume flow m³/s
\(d\) Pipe inside diameter m
\(\Sigma K\) Sum of the K values of the fittings -
\(\rho\) Fluid density kg/m³
\(f\) Darcy friction factor of the pipe (for the equivalent length) -
\(v\) Velocity m/s
\(v^2/2g\) Velocity head m
\(h_L\) Head loss Σ K v²/2g m
\(\Delta p\) Pressure drop Pa
\(L_e\) Equivalent pipe length Σ K d/f m

Method and standards

Losses proportional to the velocity head.

Where it is used

  • Pump head and line pressure drop.
  • Comparing valve types.

Common mistakes

  • Velocity of the wrong pipe size.
  • Counting the exit loss twice.

Assumptions and limits

  • Turbulent flow, K constant.

References

  • Resistance coefficient method
  • Δp = K ρ v²/2 (Textbook fluid mechanics (White, Fluid Mechanics))

Questions and answers

What do fittings with ΣK = 6.5 lose at 50 m³/h in a 4-inch pipe?

Velocity 1.69 m/s; head loss 0.95 m of water.

Where do K values come from?

Maker's data or published tables; a fully open gate valve is small, a globe valve large.

What is equivalent length?

The length of straight pipe with the same loss, K d / f.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.