FireCADCalc

Hydraulic Jump: Sequent Depth and Energy Loss

Depth after a hydraulic jump in a rectangular channel from the upstream depth and velocity (Bélanger), with the energy lost and the upstream Froude number.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 0.3 m deep at 6 m/s, 2 m wideSpillway toe: 0.15 m at 12 m/s, 5 mWeak jump: 0.5 m at 3 m/s

Results

Power with the water density entered. Horizontal rectangular channel, friction in the jump neglected.

Froude number before the jump3.4981
Depth after the jump1.3417m
Head lost (y₂ − y₁)³/(4 y₁ y₂)0.70205m
Power dissipated24.735kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.3 m deep at 6 m/s, 2 m wide. The inputs, in the units selected above:

InputValue
Depth before the jump0.30000 m
Velocity before the jump6.0000 m/s
Water density (for the power lost)998.00 kg/m³
Channel width (for the power lost)2.0000 m

Applying the formula below gives:

ResultValue
Froude number before the jump3.4981
Depth after the jump1.3417 m
Head lost (y₂ − y₁)³/(4 y₁ y₂)0.70205 m
Power dissipated24.735 kW

Open this example in the calculator and change any input.

Formula

\(Fr_1 = \frac{v_1}{\sqrt{g y_1}}, \quad \frac{y_2}{y_1} = \frac{1}{2}\left(\sqrt{1 + 8 Fr_1^2} - 1\right), \quad \Delta E = \frac{(y_2 - y_1)^3}{4 y_1 y_2}, \quad P_L = \rho g\,v_1 y_1 b\,\Delta E\)

Variables

Symbol Meaning SI unit
\(y_1\) Depth before the jump m
\(v_1\) Velocity before the jump m/s
\(\rho\) Water density (for the power lost) kg/m³
\(b\) Channel width (for the power lost) m
\(Fr_1\) Froude number before the jump -
\(y_2\) Depth after the jump m
\(\Delta E\) Head lost (y₂ − y₁)³/(4 y₁ y₂) m
\(P_L\) Power dissipated W

Method and standards

Momentum across the jump.

Where it is used

  • Spillways and outfalls.
  • Hydraulics examinations.

Common mistakes

  • Using it for sloping channels.
  • Fr from the wrong depth.

Assumptions and limits

  • Horizontal, rectangular.

References

  • Momentum balance across a jump (Bélanger); Chow
  • Open-Channel Hydraulics

Questions and answers

0.3 m deep at 6 m/s: what jump?

Fr₁ 3.50; depth after 1.34 m.

Why build stilling basins?

The jump dissipates energy safely before the water reaches the channel.

What if Fr is below 1?

The flow is already subcritical: there is no jump.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.