FireCADCalc

Vacuum Line Conductance and Effective Pumping Speed

Conductance of a round vacuum line in viscous and molecular flow, the Knudsen number, and the effective pumping speed at the chamber.

Inputs

Examples: Illustrative 100 L/s pump, 40 mm line at 10 PaRough vacuum 1 kPaHigh vacuum 0.01 Pa

Accepted: 0.001 to 100,000 L/s
Accepted: 1 to 2,000 mm
Accepted: 0.01 to 200 m
Accepted: 1E-11 to 1 bar
Accepted: -73.15 to 326.85 °C
Accepted: 1 to 400 kg/kmol
Accepted: 1E-6 to 0.0001 Pa·s

Results

In viscous (laminar) flow the conductance of a long round tube is π d⁴ p̄ /(128 μ L), proportional to pressure; in molecular flow it is (π/12) v̄ d³/L, independent of pressure. The Knudsen number λ/d shows the regime: below about 0.01 viscous, above about 0.5 molecular; between them the sum of the two is a fair estimate. The line and pump act like resistances in series: 1/S_eff = 1/S + 1/C, so a thin, long line wastes a large pump.

Mean free path0.65811mm
Knudsen number λ/d0.016453
Viscous-flow conductance17.357L/s
Molecular-flow conductance3.8784L/s
Conductance used (sum)21.235L/s
Effective pumping speed at the chamber17.516L/s
Speed lost in the line82.484%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 L/s pump, 40 mm line at 10 Pa. The inputs, in the units selected above:

InputValue
Pump speed at its inlet100.00 L/s
Line inside diameter40.000 mm
Line length2.0000 m
Mean pressure in the line1.0000e-04 bar
Gas temperature20.000 °C
Molar mass of the gas28.960 kg/kmol
Gas viscosity1.8100e-05 Pa·s

Applying the formula below gives:

ResultValue
Mean free path0.65811 mm
Knudsen number λ/d0.016453
Viscous-flow conductance17.357 L/s
Molecular-flow conductance3.8784 L/s
Conductance used (sum)21.235 L/s
Effective pumping speed at the chamber17.516 L/s
Speed lost in the line82.484 %

Open this example in the calculator and change any input.

Formula

\(C_v = \frac{\pi d^4 \bar p}{128 \mu L}, \quad C_m = \frac{\pi}{12}\bar v\frac{d^3}{L}, \quad \frac1{S_{eff}} = \frac1S + \frac1C, \quad \lambda = \frac{\mu}{p}\sqrt{\frac{\pi R T}{2M}}\)

Variables

Symbol Meaning SI unit
\(S\) Pump speed at its inlet m³/s
\(d\) Line inside diameter m
\(L\) Line length m
\(\bar p\) Mean pressure in the line Pa
\(T\) Gas temperature K
\(M\) Molar mass of the gas kg/kmol
\(\mu\) Gas viscosity Pa·s
\(\lambda\) Mean free path m
\(Kn\) Knudsen number λ/d -
\(C_v\) Viscous-flow conductance m³/s
\(C_m\) Molecular-flow conductance m³/s
\(C\) Conductance used (sum) m³/s
\(S_{eff}\) Effective pumping speed at the chamber m³/s
\(1 - S_{eff}/S\) Speed lost in the line -

Method and standards

Vacuum conductance.

Where it is used

  • Sizing vacuum lines for dryers, furnaces and coaters.
  • Judging pump-down performance.

Common mistakes

  • Using the pump's rated speed at the chamber.
  • Applying the viscous formula at high vacuum.

Assumptions and limits

  • Long round tube; isothermal; transitional flow as a sum.

References

  • Poiseuille and Knudsen conductance of a long round tube; kinetic-theory mean free path

Questions and answers

Why does my vacuum pump perform worse than its rating?

The line's conductance is in series with the pump: a 40 mm, 2 m line at 10 Pa leaves less than a fifth of a 100 L/s pump's speed at the chamber.

When is flow molecular?

When the mean free path exceeds about half the pipe diameter: for air in a 40 mm line, below roughly 0.3 Pa.

What do the defaults represent?

An illustrative 100 L/s pump on a 40 mm, 2 m line with air at a mean 10 Pa.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

O'Hanlon, A User's Guide to Vacuum Technology, 3rd ed. (Wiley, 2003)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.