Worked example
Example: Illustrative 100 L/s pump, 40 mm line at 10 Pa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pump speed at its inlet | 100.00 L/s |
| Line inside diameter | 40.000 mm |
| Line length | 2.0000 m |
| Mean pressure in the line | 1.0000e-04 bar |
| Gas temperature | 20.000 °C |
| Molar mass of the gas | 28.960 kg/kmol |
| Gas viscosity | 1.8100e-05 Pa·s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mean free path | 0.65811 mm |
| Knudsen number λ/d | 0.016453 |
| Viscous-flow conductance | 17.357 L/s |
| Molecular-flow conductance | 3.8784 L/s |
| Conductance used (sum) | 21.235 L/s |
| Effective pumping speed at the chamber | 17.516 L/s |
| Speed lost in the line | 82.484 % |
Open this example in the calculator and change any input.
Formula
\(C_v = \frac{\pi d^4 \bar p}{128 \mu L}, \quad C_m = \frac{\pi}{12}\bar v\frac{d^3}{L}, \quad \frac1{S_{eff}} = \frac1S + \frac1C, \quad \lambda = \frac{\mu}{p}\sqrt{\frac{\pi R T}{2M}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | Pump speed at its inlet | m³/s |
| \(d\) | Line inside diameter | m |
| \(L\) | Line length | m |
| \(\bar p\) | Mean pressure in the line | Pa |
| \(T\) | Gas temperature | K |
| \(M\) | Molar mass of the gas | kg/kmol |
| \(\mu\) | Gas viscosity | Pa·s |
| \(\lambda\) | Mean free path | m |
| \(Kn\) | Knudsen number λ/d | - |
| \(C_v\) | Viscous-flow conductance | m³/s |
| \(C_m\) | Molecular-flow conductance | m³/s |
| \(C\) | Conductance used (sum) | m³/s |
| \(S_{eff}\) | Effective pumping speed at the chamber | m³/s |
| \(1 - S_{eff}/S\) | Speed lost in the line | - |
Method and standards
Vacuum conductance.
Where it is used
- Sizing vacuum lines for dryers, furnaces and coaters.
- Judging pump-down performance.
Common mistakes
- Using the pump's rated speed at the chamber.
- Applying the viscous formula at high vacuum.
Assumptions and limits
- Long round tube; isothermal; transitional flow as a sum.
References
- Poiseuille and Knudsen conductance of a long round tube; kinetic-theory mean free path
Questions and answers
Why does my vacuum pump perform worse than its rating?
The line's conductance is in series with the pump: a 40 mm, 2 m line at 10 Pa leaves less than a fifth of a 100 L/s pump's speed at the chamber.
When is flow molecular?
When the mean free path exceeds about half the pipe diameter: for air in a 40 mm line, below roughly 0.3 Pa.
What do the defaults represent?
An illustrative 100 L/s pump on a 40 mm, 2 m line with air at a mean 10 Pa.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
O'Hanlon, A User's Guide to Vacuum Technology, 3rd ed. (Wiley, 2003)