Fibre Critical Length and Short Fibre Composite Strength

Critical fibre length from fibre strength, diameter and interface shear strength, and the strength of an aligned discontinuous fibre composite.

Inputs

Examples: Illustrative chopped fibre 3 mmLong glass fibre 12 mmMilled fibre shorter than critical

Accepted: 100 to 10,000 MPa
Accepted: 1 to 1,000 µm
Accepted: 1 to 500 MPa
Accepted: 0.01 to 100 mm
Accepted: 1 to 80 %
Accepted: 1 to 1,000 MPa

Results

Stress builds up along a fibre by interface shear and reaches the fibre strength only beyond half the critical length l_c = σ*_fd/(2τ_c). For l > l_c: σ*_cd = σ*_fV_f(1 − l_c/2l) + σ′_m(1 − V_f); for l < l_c the fibres never break and σ*_cd′ = (lτ_c/d)V_f + σ′_m(1 − V_f). Fibres longer than about 15 l_c behave almost as continuous.

Critical fibre length0.62500mm
Length ratio19.200
Composite strength758.47MPa
Strength if fibres were continuous778.00MPa
Strength efficiency97.490%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative chopped fibre 3 mm. The inputs, in the units selected above:

InputValue
Fibre tensile strength3,400.0 MPa
Fibre diameter10.000 µm
Fibre-matrix bond (shear) strength40.000 MPa
Fibre length3.0000 mm
Fibre volume fraction30.000 %
Matrix stress at composite failure50.000 MPa

Applying the formula below gives:

ResultValue
Critical fibre length0.42500 mm
Length ratio7.0588
Composite strength982.75 MPa
Strength if fibres were continuous1,055.0 MPa
Strength efficiency93.152 %

Open this example in the calculator and change any input.

Formula

\(l_c = \frac{\sigma_f^*d}{2\tau_c}, \quad \sigma_{cd}^* = \sigma_f^*V_f\left(1 - \frac{l_c}{2l}\right) + \sigma_m'(1 - V_f)\)

Variables

Symbol Meaning SI unit
\(\sigma_f^*\) Fibre tensile strength Pa
\(d\) Fibre diameter m
\(\tau_c\) Fibre-matrix bond (shear) strength Pa
\(l\) Fibre length m
\(V_f\) Fibre volume fraction -
\(\sigma_m'\) Matrix stress at composite failure Pa
\(l_c\) Critical fibre length m
\(l/l_c\) Length ratio -
\(\sigma_{cd}^*\) Composite strength Pa
\(\sigma_{cl}^*\) Strength if fibres were continuous Pa
\(\sigma_{cd}^*/\sigma_{cl}^*\) Strength efficiency -

Method and standards

Critical length.

Where it is used

  • Short-fibre moulding compounds.
  • Choosing chopped fibre length.

Common mistakes

  • Using fibre radius instead of diameter.
  • Ignoring fibre attrition during moulding.

Assumptions and limits

  • Aligned fibres; constant interface shear (Kelly–Tyson).

References

  • Shear-lag critical length (Kelly–Tyson)

Questions and answers

Why does fibre length matter?

Fibre ends carry little stress; short fibres pull out before they break, wasting their strength.

How long should chopped fibres be?

Several times the critical length; at 15 l_c the efficiency is above 95 %.

What do the defaults represent?

An illustrative chopped glass or carbon fibre: 3.4 GPa, 10 µm diameter, 40 MPa bond strength, 3 mm long at 30 % volume.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Callister and Rethwisch, Materials Science and Engineering: An Introduction (Wiley)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.