FireCADCalc

Trickling Filter BOD Removal (NRC Equation)

BOD removal efficiency of a single-stage stone trickling filter from BOD load, media volume and recirculation by the NRC equation, corrected for temperature.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 4000 m3/d, 180 mg/L, 25 m x 2 m, R 1.5, 20 °CWinter 12 °C, no recirculation

Results

The NRC equation comes from military-camp stone filters treating domestic sewage after primary settling; apply it to plastic media and industrial wastes with care.

BOD load300.00kg/d
Media volume458.04m³
Recirculation factor1.0000
Efficiency at 20 °C73.601%
Efficiency at T55.893%
Effluent BOD66.160mg/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 4000 m3/d, 180 mg/L, 25 m x 2 m, R 1.5, 20 °C. The inputs, in the units selected above:

InputValue
Wastewater flow4,000.0 m³/d
Settled influent BOD180.00 mg/L
Filter diameter25.000 m
Media depth2.0000 m
Recirculation ratio1.5000 -
Wastewater temperature20.000 °C

Applying the formula below gives:

ResultValue
BOD load720.00 kg/d
Media volume981.75 m³
Recirculation factor1.8904
Efficiency at 20 °C78.367 %
Efficiency at T78.367 %
Effluent BOD38.940 mg/L

Open this example in the calculator and change any input.

Formula

\(E = \frac{100}{1 + 0.4432\sqrt{\dfrac{W}{VF}}}, \quad F = \frac{1 + R}{(1 + R/10)^2}, \quad E_T = \min\left(E_{20}\,1.035^{T - 20},\ 0.99\right)\ \ (W\ \mathrm{kg/d},\ V\ \mathrm{m^3})\)

Variables

Symbol Meaning SI unit
\(Q\) Wastewater flow m³/s
\(BOD\) Settled influent BOD kg/m³
\(D\) Filter diameter m
\(H\) Media depth m
\(R\) Recirculation ratio -
\(T\) Wastewater temperature K
\(W\) BOD load kg/s
\(V\) Media volume m³
\(F\) Recirculation factor -
\(E_{20}\) Efficiency at 20 °C -
\(E_T\) Efficiency at T -
\(BOD_e\) Effluent BOD kg/m³

Method and standards

NRC first-stage equation.

Where it is used

  • Upgrading and checking existing filters.
  • Roughing filters before activated sludge.

Common mistakes

  • Using raw instead of settled BOD.
  • Applying it to high-rate plastic media.

Assumptions and limits

  • The temperature-corrected efficiency is capped at 99 % (the page says when the cap applies); the NRC equation was not fitted to removals that high.

  • Single stage; domestic-type wastewater.

References

  • Metcalf & Eddy
  • Wastewater Engineering: Treatment and Resource Recovery
  • 5th ed. (McGraw-Hill, 2014)
  • ch. 9 (NRC equations for stone-media trickling filters, SI form, θ = 1.035)

Questions and answers

What does recirculation do?

It dilutes the feed and wets the media better; the NRC factor F rises from 1 with no recirculation to 2.75 at R = 10.

Why does temperature matter?

Biological rates fall in cold weather: about 3.5 % per °C.

What do the defaults give?

4,000 m³/d at 180 mg/L on a 25 m × 2 m filter with R 1.5: about 78 % removal.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.