Worked example
Example: 1500 m3 basin. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Aeration tank volume | 1,500.0 m³ |
| MLSS | 3,000.0 mg/L |
| Waste sludge flow (from the return line) | 35.000 m³/d |
| Return sludge concentration | 10,000 mg/L |
| Effluent flow | 2,000.0 m³/d |
| Effluent suspended solids | 20.000 mg/L |
| Target sludge age | 10.000 d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Solids in the aeration tank | 4,500.0 kg |
| Present sludge age | 11.538 d |
| Waste flow for the target | 41.000 m³/d |
Open this example in the calculator and change any input.
Formula
\(\theta_c = \frac{V X}{Q_w X_r + Q_e X_e}, \quad Q_{w,t} = \frac{VX/\theta_t - Q_e X_e}{X_r}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Aeration tank volume | m³ |
| \(X\) | MLSS | kg/m³ |
| \(Q_w\) | Waste sludge flow (from the return line) | m³/s |
| \(X_r\) | Return sludge concentration | kg/m³ |
| \(Q_e\) | Effluent flow | m³/s |
| \(X_e\) | Effluent suspended solids | kg/m³ |
| \(\theta_t\) | Target sludge age | s |
| \(M\) | Solids in the aeration tank | kg |
| \(\theta_c\) | Present sludge age | s |
| \(Q_{w,t}\) | Waste flow for the target | m³/s |
Method and standards
Solids balance.
Where it is used
- ETP operation.
- Operator examinations.
Common mistakes
- Ignoring effluent solids.
- Wasting from the tank at MLSS but using X_r.
Assumptions and limits
- Steady state.
- If no solids leave, the sludge age is not defined and is not shown. If the effluent solids alone exceed the loss the target allows, the waste flow is 0 and the page warns that the target cannot be met.
References
- θ_c = V X/(Q_w X_r + Q_e X_e) (Metcalf & Eddy)
Questions and answers
1500 m³ at 3000 mg/L, wasting 35 m³/d at 10,000 mg/L?
Sludge age about 11.5 days.
For 10 days?
Waste about 41 m³/d.
Why control SRT?
It sets the biology: nitrifiers need longer sludge ages.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.