Settling Tank: Detention Time, Overflow Rate and Weir Loading

Detention time, surface overflow rate and weir loading of a rectangular or circular settling tank from flow and tank dimensions.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Circular clarifier 20 mRectangular 30 x 8 m with 40 m of weir

Results

With no weir length given: the end width of a rectangular tank, the perimeter of a circular one.

Surface area240.00m²
Volume720.00m³
Detention time2.4000h
Surface overflow rate1.2500m/h
Weir loading180.00m³/(d·m)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Circular clarifier 20 m. The inputs, in the units selected above:

InputValue
Flow400.00 m³/h
Tank shapeCircular
Length (rectangular)30.000 m
Width (rectangular)8.0000 m
Diameter (circular)20.000 m
Side water depth3.5000 m
Total outlet weir length (0: end width of a rectangular tank, perimeter of a circular one)0 m

Applying the formula below gives:

ResultValue
Surface area314.16 m²
Volume1,099.6 m³
Detention time2.7489 h
Surface overflow rate1.2732 m/h
Weir loading152.79 m³/(d·m)

Open this example in the calculator and change any input.

Formula

\(t_d = \frac{V}{\dot V}, \quad v_o = \frac{\dot V}{A}, \quad q_w = \frac{\dot V}{L_w}\)

Variables

Symbol Meaning SI unit
\(\dot V\) Flow m³/s
\(\text{shape}\) Tank shape -
\(L\) Length (rectangular) m
\(W\) Width (rectangular) m
\(D\) Diameter (circular) m
\(H\) Side water depth m
\(L_w\) Total outlet weir length (0: end width of a rectangular tank, perimeter of a circular one) m
\(A\) Surface area m²
\(V\) Volume m³
\(t_d\) Detention time s
\(v_o\) Surface overflow rate m/s
\(q_w\) Weir loading m³/(s·m)

Method and standards

Definitions.

Where it is used

  • Clarifiers for raw water and effluent.
  • Ash pond and settling pit checks.

Common mistakes

  • Using total depth with sludge zone.
  • Peak vs average flow.

Assumptions and limits

  • Uniform flow.
  • With zero flow the detention time is not defined and is not shown.

References

  • Detention time V/Q
  • surface overflow rate Q/A
  • weir loading Q/L_w (Metcalf & Eddy; water treatment texts)

Questions and answers

400 m³/h in a 20 m circular tank, 3.5 m deep?

Detention 2.7 h, overflow 1.27 m/h, weir loading 153 m³/(d·m).

Which limits apply?

Your design standard's, by tank type and solids.

Short-circuiting?

Real detention is shorter than V/Q; baffles help.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.