Worked example
Example: 100 m³/h at 3,000 mg/L, 30 m³/h recycle at 4.5 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Air solubility at the temperature (mL/L) | 18.700 - |
| Fraction of saturation achieved | 50.000 % |
| Saturator pressure (absolute) | 4.5000 bar |
| Pressurised recycle flow | 30.000 m³/h |
| Feed flow | 100.00 m³/h |
| Feed suspended solids (mg/L) | 3,000.0 - |
| Target air-to-solids ratio | 0.020000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air-to-solids ratio (mL/mg × 1.3) | 0.002967 |
| Recycle for the target A/S | 202.21 m³/h |
Open this example in the calculator and change any input.
Formula
\(\frac AS = \frac{1.3s_a(fP - 1)R}{QS_a}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(s_a\) | Air solubility at the temperature (mL/L) | - |
| \(f\) | Fraction of saturation achieved | - |
| \(P\) | Saturator pressure (absolute) | Pa |
| \(R\) | Pressurised recycle flow | m³/s |
| \(Q\) | Feed flow | m³/s |
| \(S_a\) | Feed suspended solids (mg/L) | - |
| \((A/S)_t\) | Target air-to-solids ratio | - |
| \(A/S\) | Air-to-solids ratio (mL/mg × 1.3) | - |
| \(R_t\) | Recycle for the target A/S | m³/s |
Method and standards
Air-to-solids ratio.
Where it is used
- Oily effluent and paper-mill fibre recovery.
- Sludge thickening.
Common mistakes
- Using gauge pressure.
- Ignoring temperature effect on solubility.
Assumptions and limits
- Pressurised recycle system.
- An A/S outside the typical 0.005–0.06 is flagged.
References
- Air-to-solids relation for pressurised recycle (Metcalf & Eddy, Wastewater Engineering, 5th ed. (McGraw-Hill, 2014), ch. 5 and 14)
Questions and answers
What does A/S control?
Enough released air bubbles must attach to the solids to float them; too little leaves solids behind.
Why recycle instead of pressurising the feed?
Pressurising clear recycle avoids shearing fragile floc and blocking the saturator.
What do the defaults represent?
100 m³/h of oily or sludge feed at 3,000 mg/L with 30 m³/h recycle saturated at 4.5 bar(a).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.