FireCADCalc

Electric Water Heater Power and Heating Time

Heater power to warm a volume of water through a temperature rise in a given time, the energy used, and the heating time with a given heater.

Thermal power plantProcess steam and utilitiesIAPWS-IF97 (water and steam)

Inputs

Examples: 200 L from 25 to 60 °C in 1 h, 95 %; 3 kW heater15 L geyser 20 to 55 °C in 10 min; 2 kW5 m³ tank 30 to 80 °C in 8 h, 90 %; 36 kW

Results

Tank heat loss during heating is inside the efficiency; for long heating times allow for standing losses.

Mass of water4,978.3kg
Heat needed289.23kWh
Electrical energy used321.37kWh
Heater power for the time allowed40.171kW
Heating time with the heater available535.62min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 200 L from 25 to 60 °C in 1 h, 95 %; 3 kW heater. The inputs, in the units selected above:

InputValue
Volume of water200.00 L
Starting temperature25.000 °C
Final temperature60.000 °C
Time allowed60.000 min
Heater efficiency (heat into the water)95.000 %
Heater available (to find the time)3.0000 kW

Applying the formula below gives:

ResultValue
Mass of water199.41 kg
Heat needed8.1034 kWh
Electrical energy used8.5299 kWh
Heater power for the time allowed8.5299 kW
Heating time with the heater available170.60 min

Open this example in the calculator and change any input.

Formula

\(Q = m\,(h_2 - h_1) \approx m\, c_p\, \Delta T, \quad P = \frac{Q}{\eta\, t}\)

Variables

Symbol Meaning SI unit
\(V\) Volume of water m³
\(T_1\) Starting temperature K
\(T_2\) Final temperature K
\(t\) Time allowed s
\(\eta\) Heater efficiency (heat into the water) -
\(P_a\) Heater available (to find the time) W
\(m\) Mass of water kg
\(Q\) Heat needed J
\(E\) Electrical energy used J
\(P\) Heater power for the time allowed W
\(t_h\) Heating time with the heater available s

Method and standards

Energy balance on the water with IF97 enthalpies.

Where it is used

  • Geysers, calorifiers and process tanks.
  • Checking immersion heaters.

Common mistakes

  • Forgetting efficiency and losses.
  • Using litres as kg at high temperature.

Assumptions and limits

  • Open tank at atmospheric pressure, below boiling.

References

  • Q = m (h₂ − h₁)
  • IAPWS-IF97 water at 1 atm

Questions and answers

What power heats 200 L from 25 °C to 60 °C in an hour?

About 8.5 kW at 95 % efficiency (8.1 kWh of heat).

How long with a 3 kW heater?

About 2 h 50 min.

Is 1.163 Wh per litre per kelvin right?

Yes, near room temperature; this calculator uses the exact enthalpy of water.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.