Mine Natural Ventilation Pressure from Air Columns

Natural ventilating pressure from the weights of the intake and return air columns (humid-air densities) and the air it drives through the mine resistance.

IAPWS-IF97 (water and steam)Fan and blower

Inputs

Examples: Peele's example: 500 ft shaft, 32 F outside, 55 F insideDeep mine in winter, 600 mSummer reversal, 300 m

Results

Columns of equal height with mean temperatures; densities at the surface barometric pressure (the compression of air with depth adds roughly equally to both columns). Natural pressure acts with or against a fan.

The return column is heavier: natural draft opposes the designed direction (typical in summer).

Intake air density1.1106kg/m³
Return air density1.1455kg/m³
Natural ventilating pressure (negative = reversed)-102.71Pa
Natural air flow through the mine (negative = reversed)-58.511m³/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Peele's example: 500 ft shaft, 32 F outside, 55 F inside. The inputs, in the units selected above:

InputValue
Depth (height of the air columns)152.40 m
Mean temperature of the intake column0 °C
Relative humidity of the intake air50.000 %
Mean temperature of the return column12.778 °C
Relative humidity of the return air95.000 %
Barometric pressure101.59 kPa
Mine resistance (N·s²/m⁸)0.050000 -

Applying the formula below gives:

ResultValue
Intake air density1.2942 kg/m³
Return air density1.2314 kg/m³
Natural ventilating pressure (negative = reversed)93.994 Pa
Natural air flow through the mine (negative = reversed)43.358 m³/s

Open this example in the calculator and change any input.

Formula

\(NVP = gH(\rho_i - \rho_r), \quad Q = \sqrt{\frac{NVP}{R}}\)

Variables

Symbol Meaning SI unit
\(H\) Depth (height of the air columns) m
\(T_i\) Mean temperature of the intake column K
\(\phi_i\) Relative humidity of the intake air -
\(T_r\) Mean temperature of the return column K
\(\phi_r\) Relative humidity of the return air -
\(p_b\) Barometric pressure Pa
\(R\) Mine resistance (N·s²/m⁸) -
\(\rho_i\) Intake air density kg/m³
\(\rho_r\) Return air density kg/m³
\(NVP\) Natural ventilating pressure (negative = reversed) Pa
\(Q\) Natural air flow through the mine (negative = reversed) m³/s

Method and standards

Difference of air-column weights.

Where it is used

  • Mine ventilation planning and fan selection.
  • Explaining seasonal airflow changes.

Common mistakes

  • Ignoring humidity in warm return air.
  • Treating natural pressure as constant through the year.

Assumptions and limits

  • Equal column heights; mean column conditions.

References

  • Peele (ed.)
  • Mining Engineers' Handbook
  • 3rd ed. (Wiley, 1941)
  • sec. 14
  • Mine Ventilation
  • art. 12 (natural draft) and its worked example
  • IAPWS-IF97 saturation pressure for the humid-air densities

Questions and answers

Why does natural ventilation change with the seasons?

Cold winter intake air is denser than warm mine air, driving air down the intake; in summer the difference shrinks or reverses.

How big is it?

Peele's example of a 500 ft shaft with 32 °F outside and 55 °F inside air gives about 2 lb/ft², roughly 94 Pa.

What do the defaults represent?

Peele's example: 500 ft columns, outside air 32 °F at 50 % and mine air 55 °F at 95 %, barometer 30 inHg, through a 0.05 N·s²/m⁸ mine.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.