Worked example
Example: Wills Example 9.2 fit: d50c 125 µm, m 1.7, bypass 32 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Corrected cut size | 125.00 µm |
| Sharpness of separation | 1.7000 - |
| Bypass (fraction of feed water to underflow) | 32.000 % |
| Particle size of interest | 150.00 µm |
| Identical classifiers in series (each re-treating the overflow) | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Corrected partition to underflow | 61.132 % |
| Actual partition to underflow | 73.570 % |
| Actual cut size (S = 50 %) | 77.493 µm |
| Size with 25 % corrected partition | 74.517 µm |
| Size with 75 % corrected partition | 187.93 µm |
| Imperfection | 0.45364 |
| Recovery of size d to the combined underflow of N in series | 73.570 % |
Open this example in the calculator and change any input.
Formula
\(C(d) = 1 - \exp\left[-0.693\left(\frac{d}{d_{50c}}\right)^m\right], \quad S = R_f + (1 - R_f)C, \quad I = \frac{d_{75} - d_{25}}{2d_{50}}, \quad R_N = 1 - (1 - S)^N\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_{50c}\) | Corrected cut size | m |
| \(m\) | Sharpness of separation | - |
| \(R_f\) | Bypass (fraction of feed water to underflow) | - |
| \(d\) | Particle size of interest | m |
| \(N\) | Identical classifiers in series (each re-treating the overflow) | - |
| \(C(d)\) | Corrected partition to underflow | - |
| \(S(d)\) | Actual partition to underflow | - |
| \(d_{50}\) | Actual cut size (S = 50 %) | m |
| \(d_{25}\) | Size with 25 % corrected partition | m |
| \(d_{75}\) | Size with 75 % corrected partition | m |
| \(I\) | Imperfection | - |
| \(R_N(d)\) | Recovery of size d to the combined underflow of N in series | - |
Method and standards
Partition curve with bypass.
Where it is used
- Evaluating cyclone surveys.
- Grinding circuit simulation.
Common mistakes
- Fitting the actual curve without removing bypass.
- Reading d50 from the corrected curve as the actual cut.
Assumptions and limits
- Plitt/Whiten curve shape; bypass equal to water split.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 9
- eqs. 9.16-9.19 (Plitt, 1976; Kelsall, 1953)
- eq. 9.28 (Svarovsky and Thew, 1984) and Example 9.2
Questions and answers
What is the bypass?
Fine particles that follow the water to the underflow without being classified; it equals roughly the water split to underflow.
Why are actual and corrected cut sizes different?
The bypass lifts the whole curve, so the actual 50 % point falls at a finer size than the corrected one.
What do the defaults represent?
Wills's Example 9.2 fit: d50c 125 µm, m 1.7 and 32 % water to underflow, read at 150 µm.