Worked example
Example: Wills Table 11.4: 1.30-1.40 fraction, coal vessel (Ep 0.12). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed reporting to floats | 82.600 % |
| Fraction in the floats analysis | 10.500 % |
| Fraction in the sinks analysis | 10.820 % |
| Density with 25 % to sinks | 1.3700 g/cm³ |
| Separating density (50 % to sinks) | 1.5200 g/cm³ |
| Density with 75 % to sinks | 1.6100 g/cm³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fraction in floats, % of feed | 8.6730 % |
| Fraction in sinks, % of feed | 1.8827 % |
| Reconstituted feed in this fraction | 10.556 % |
| Partition coefficient to sinks | 17.836 % |
| Ecart probable | 0.12000 g/cm³ |
Open this example in the calculator and change any input.
Formula
\(P = \frac{a_s(1 - Y_f)}{a_f Y_f + a_s(1 - Y_f)}, \quad E_p = \frac{\rho_{75} - \rho_{25}}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Y_f\) | Feed reporting to floats | - |
| \(a_f\) | Fraction in the floats analysis | - |
| \(a_s\) | Fraction in the sinks analysis | - |
| \(\rho_{25}\) | Density with 25 % to sinks | kg/m³ |
| \(\rho_{50}\) | Separating density (50 % to sinks) | kg/m³ |
| \(\rho_{75}\) | Density with 75 % to sinks | kg/m³ |
| \(a_f Y_f\) | Fraction in floats, % of feed | - |
| \(a_s(1 - Y_f)\) | Fraction in sinks, % of feed | - |
| \(\Sigma\) | Reconstituted feed in this fraction | - |
| \(P\) | Partition coefficient to sinks | - |
| \(E_p\) | Ecart probable | kg/m³ |
Method and standards
Partition coefficient and probable error.
Where it is used
- Coal preparation plant performance tests.
- Comparing dense-medium cyclones and baths.
Common mistakes
- Using float-sink percentages without the product yields.
- Plotting fractions at the wrong nominal density.
Assumptions and limits
- Representative product samples.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 11
- eq. 11.3 (Tromp, 1937) and Table 11.4
Questions and answers
How are the float and sink analyses made?
Samples of each product are separated in heavy liquids over a range of densities around the working density, and each fraction weighed.
What is a good Ep?
Lower is sharper; Wills's coal vessel example gives about 0.12 at an RD50 of 1.52. Centrifugal separators usually beat static baths on fine coal.
What do the defaults represent?
The 1.30–1.40 fraction of Wills's Table 11.4 (82.6 % to floats; 17.84 % partition) and its curve's ρ25 1.37, ρ50 1.52 and ρ75 1.61.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.