FireCADCalc

Dense-Medium Partition Coefficient and Ecart Probable

Partition coefficient of a density fraction to sinks from float and sink analyses and the floats yield, and the Ecart probable (Ep) of a dense-medium separator.

Inputs

Examples: Wills Table 11.4: 1.30-1.40 fraction, coal vessel (Ep 0.12)Wills Table 11.4: 1.50-1.60 fractionIron ore DMS cyclone

Results

Repeat for each density fraction (plotted at its mid density) to build the partition curve, then read ρ25, ρ50 and ρ75 from it. A lower Ep means a sharper separation; Ep does not describe the tails of the curve.

Fraction in floats, % of feed8.6730%
Fraction in sinks, % of feed1.8827%
Reconstituted feed in this fraction10.556%
Partition coefficient to sinks17.836%
Ecart probable0.12000g/cm³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Wills Table 11.4: 1.30-1.40 fraction, coal vessel (Ep 0.12). The inputs, in the units selected above:

InputValue
Feed reporting to floats82.600 %
Fraction in the floats analysis10.500 %
Fraction in the sinks analysis10.820 %
Density with 25 % to sinks1.3700 g/cm³
Separating density (50 % to sinks)1.5200 g/cm³
Density with 75 % to sinks1.6100 g/cm³

Applying the formula below gives:

ResultValue
Fraction in floats, % of feed8.6730 %
Fraction in sinks, % of feed1.8827 %
Reconstituted feed in this fraction10.556 %
Partition coefficient to sinks17.836 %
Ecart probable0.12000 g/cm³

Open this example in the calculator and change any input.

Formula

\(P = \frac{a_s(1 - Y_f)}{a_f Y_f + a_s(1 - Y_f)}, \quad E_p = \frac{\rho_{75} - \rho_{25}}{2}\)

Variables

Symbol Meaning SI unit
\(Y_f\) Feed reporting to floats -
\(a_f\) Fraction in the floats analysis -
\(a_s\) Fraction in the sinks analysis -
\(\rho_{25}\) Density with 25 % to sinks kg/m³
\(\rho_{50}\) Separating density (50 % to sinks) kg/m³
\(\rho_{75}\) Density with 75 % to sinks kg/m³
\(a_f Y_f\) Fraction in floats, % of feed -
\(a_s(1 - Y_f)\) Fraction in sinks, % of feed -
\(\Sigma\) Reconstituted feed in this fraction -
\(P\) Partition coefficient to sinks -
\(E_p\) Ecart probable kg/m³

Method and standards

Partition coefficient and probable error.

Where it is used

  • Coal preparation plant performance tests.
  • Comparing dense-medium cyclones and baths.

Common mistakes

  • Using float-sink percentages without the product yields.
  • Plotting fractions at the wrong nominal density.

Assumptions and limits

  • Representative product samples.

References

  • Wills and Finch
  • Wills' Mineral Processing Technology
  • 8th ed. (Butterworth-Heinemann, 2016)
  • ch. 11
  • eq. 11.3 (Tromp, 1937) and Table 11.4

Questions and answers

How are the float and sink analyses made?

Samples of each product are separated in heavy liquids over a range of densities around the working density, and each fraction weighed.

What is a good Ep?

Lower is sharper; Wills's coal vessel example gives about 0.12 at an RD50 of 1.52. Centrifugal separators usually beat static baths on fine coal.

What do the defaults represent?

The 1.30–1.40 fraction of Wills's Table 11.4 (82.6 % to floats; 17.84 % partition) and its curve's ρ25 1.37, ρ50 1.52 and ρ75 1.61.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.