Worked example
Example: Wills Example 7.2: ball mill in closed circuit with cyclones. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed 80 % passing size | 600.00 µm |
| Product 80 % passing size | 110.00 µm |
| Bond work index (laboratory) | 10.500 kWh/t |
| Throughput (dry solids) | 150.00 t/h |
| Product of Rowland's efficiency factors (1 if none) | 1.0000 - |
| Measured mill power at the pinion (for the operating work index) | 900.00 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific energy | 5.7248 kWh/t |
| Mill power required | 858.71 kW |
| Operating work index from measured power | 11.005 kWh/t |
| Circuit efficiency (laboratory over operating index) | 95.413 % |
Open this example in the calculator and change any input.
Formula
\(W = 10 W_i\left(\frac{1}{\sqrt{P_{80}}} - \frac{1}{\sqrt{F_{80}}}\right) EF_x, \quad P = W T, \quad W_{io} = \frac{P_m/T}{10\left(1/\sqrt{P_{80}} - 1/\sqrt{F_{80}}\right)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F_{80}\) | Feed 80 % passing size | m |
| \(P_{80}\) | Product 80 % passing size | m |
| \(W_i\) | Bond work index (laboratory) | J/kg |
| \(T\) | Throughput (dry solids) | kg/s |
| \(EF_x\) | Product of Rowland's efficiency factors (1 if none) | - |
| \(P_m\) | Measured mill power at the pinion (for the operating work index) | W |
| \(W\) | Specific energy | J/kg |
| \(P\) | Mill power required | W |
| \(W_{io}\) | Operating work index from measured power | J/kg |
| \(W_i/W_{io}\) | Circuit efficiency (laboratory over operating index) | - |
Method and standards
Bond's equation with Rowland's efficiency factors.
Where it is used
- Sizing rod and ball mills.
- Benchmarking grinding circuits.
Common mistakes
- Using motor input instead of pinion power.
- Applying the ball-mill index to SAG milling.
Assumptions and limits
- Wet closed-circuit grinding; Bond's calibration range.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 5
- eq. 5.4 (Bond, 1952) and ch. 7
- eq. 7.11 (Rowland and Kjos, 1980)
- Example 7.2
Questions and answers
What is the operating work index used for?
Compared with the laboratory index it shows how efficiently a circuit grinds; a rising operating index means harder ore or a less efficient circuit.
Which sizes go into the equation?
The 80 % passing sizes of the circuit feed and the circuit product (cyclone overflow), in micrometres.
What do the defaults represent?
Wills's Example 7.2: closed-circuit ball mill from 600 to 110 µm, Wi 10.5 kWh/t, 150 t/h (5.72 kWh/t, 859 kW), with 900 kW measured.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.