Worked example
Example: Three splits in parallel, 90 m3/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Arrangement | Parallel (splits begin and end together) |
| Resistance of airway 1 (N·s²/m⁸) | 0.080000 - |
| Resistance of airway 2 (0 if none) | 0.12000 - |
| Resistance of airway 3 (0 if none) | 0.20000 - |
| Resistance of airway 4 (0 if none) | 0 - |
| Total air flow | 90.000 m³/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Equivalent resistance (N·s²/m⁸) | 0.013339 |
| Pressure drop across the group | 108.05 Pa |
| Flow in airway 1 | 36.750 m³/s |
| Flow in airway 2 | 30.007 m³/s |
| Flow in airway 3 | 23.243 m³/s |
| Flow in airway 4 | 0 m³/s |
Open this example in the calculator and change any input.
Formula
\(R_{series} = \sum R_i, \quad \frac{1}{\sqrt{R_{par}}} = \sum\frac{1}{\sqrt{R_i}}, \quad Q_i = Q\sqrt{\frac{R_{par}}{R_i}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{arrangement}\) | Arrangement | - |
| \(R_1\) | Resistance of airway 1 (N·s²/m⁸) | - |
| \(R_2\) | Resistance of airway 2 (0 if none) | - |
| \(R_3\) | Resistance of airway 3 (0 if none) | - |
| \(R_4\) | Resistance of airway 4 (0 if none) | - |
| \(Q\) | Total air flow | m³/s |
| \(R_{eq}\) | Equivalent resistance (N·s²/m⁸) | - |
| \(p\) | Pressure drop across the group | Pa |
| \(Q_1\) | Flow in airway 1 | m³/s |
| \(Q_2\) | Flow in airway 2 | m³/s |
| \(Q_3\) | Flow in airway 3 | m³/s |
| \(Q_4\) | Flow in airway 4 | m³/s |
Method and standards
Square-law combination of airways.
Where it is used
- Mine ventilation surveys and planning.
- Placing regulators.
Common mistakes
- Adding parallel resistances directly.
- Mixing resistance units between airways.
Assumptions and limits
- Square law; no cross-connections.
References
- Peele (ed.)
- Mining Engineers' Handbook
- 3rd ed. (Wiley, 1941)
- sec. 14
- Mine Ventilation
- art. 13 (series flow, parallel or split flow, natural splitting)
Questions and answers
Why does air not divide equally between splits?
Each split takes air in proportion to 1/√R, so a split with a quarter the resistance takes twice the air.
How are networks with cross-connections handled?
Peele ignores cross-connections for an approximate answer; exact networks need an iterative (Hardy Cross) solution.
What do the defaults represent?
Three parallel splits of 0.08, 0.12 and 0.20 N·s²/m⁸ sharing 90 m³/s.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.