Shell-and-Tube Tube-Side Pressure Drop with Return and Nozzle Losses

Tube-side friction, entrance, exit and return losses by the velocity-head allowances, and nozzle losses, for regular or U-tube shell-and-tube exchangers.

Thermal power plantRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Cooling water, 2 passes, U-tubes, 6 mViscous oil in laminar flow, 6 passes, two shells

Accepted: 3.6 to 3,600,000 kg/h
Accepted: 3 to 60 mm
Accepted: 1 to 20,000
Accepted: 1 to 16
Accepted: 0.3 to 30 m
Accepted: 0.5 to 2,000 kg/m³
Accepted: 0.001 to 1,000 mPa·s
Accepted: 0.05 to 20
Accepted: 10 to 1,000 mm
Accepted: 1 to 10

Results

The allowances: turbulent 2n_p − 1.5 velocity heads (U-tubes 1.6n_p − 1.5); laminar with Re ≥ 500, 3.25n_p − 1.5 (U-tubes 2.38n_p − 1.5). Nozzles: 0.75 G_n²/ρ per shell turbulent, 1.5 G_n²/ρ laminar.

Laminar flow below Re 500: the minor-loss allowance is uncertain.

Tube-side Reynolds number240.23
Tube velocity0.62954m/s
Tube-side mass flux566.59kg/(m²·s)
Darcy friction factor0.26641
Friction loss in the tubes52.155kPa
Velocity heads for entrance, exit and return losses18.000
Entrance, exit and return losses3.2102kPa
Nozzle Reynolds number980.67
Nozzle losses (all shells)1.3207kPa
Total tube-side pressure drop56.686kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Cooling water, 2 passes, U-tubes, 6 m. The inputs, in the units selected above:

InputValue
Tube-side mass flow216,000 kg/h
Tube inside diameter15.700 mm
Number of tubes400.00 -
Number of tube passes2.0000 -
Tube length6.0000 m
Density995.00 kg/m³
Viscosity0.75000 mPa·s
Viscosity ratio bulk to wall1.1000 -
Tube typeU-tubes
Nozzle inside diameter200.00 mm
Shells in series1.0000 -

Applying the formula below gives:

ResultValue
Tube-side Reynolds number32,439
Tube velocity1.5574 m/s
Tube-side mass flux1,549.6 kg/(m²·s)
Darcy friction factor0.028221
Friction loss in the tubes25.685 kPa
Velocity heads for entrance, exit and return losses1.7000
Entrance, exit and return losses2.0514 kPa
Nozzle Reynolds number509,296
Nozzle losses (all shells)2.7494 kPa
Total tube-side pressure drop30.485 kPa

Open this example in the calculator and change any input.

Formula

\(\Delta P_f = \frac{fn_pLG^2}{2\rho D_i\phi}, \quad f = 0.4137Re^{-0.2585}\)

\(\Delta P_r = \alpha_r\frac{G^2}{2\rho}, \quad \alpha_r = 2n_p - 1.5 \;(\text{turbulent}), \quad \Delta P_n = 0.75N_s\frac{G_n^2}{\rho}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Tube-side mass flow kg/s
\(D_i\) Tube inside diameter m
\(n_t\) Number of tubes -
\(n_p\) Number of tube passes -
\(L\) Tube length m
\(\rho\) Density kg/m³
\(\mu\) Viscosity Pa·s
\(\mu/\mu_w\) Viscosity ratio bulk to wall -
\(\text{tubes}\) Tube type -
\(D_n\) Nozzle inside diameter m
\(N_s\) Shells in series -
\(Re\) Tube-side Reynolds number -
\(V\) Tube velocity m/s
\(G\) Tube-side mass flux kg/(m²·s)
\(f\) Darcy friction factor -
\(\Delta P_f\) Friction loss in the tubes Pa
\(\alpha_r\) Velocity heads for entrance, exit and return losses -
\(\Delta P_r\) Entrance, exit and return losses Pa
\(Re_n\) Nozzle Reynolds number -
\(\Delta P_n\) Nozzle losses (all shells) Pa
\(\Delta P_i\) Total tube-side pressure drop Pa

Method and standards

Darcy friction in the tubes plus velocity-head allowances for headers and nozzles.

Where it is used

  • Checking the tube-side pressure drop when choosing the number of passes.
  • Rating existing exchangers.

Common mistakes

  • Using the total mass flux instead of the flow per pass.
  • Omitting the nozzle losses.

Assumptions and limits

  • Single-phase flow; viscosity correction (μ/μ_w)^0.14 turbulent, ^0.25 laminar.

Questions and answers

Why not use four velocity heads per pass?

Kern's four per pass is conservative; the analysis of entrance, exit and return losses gives about 2n_p − 1.5 in turbulent flow, close to HEXTRAN's two per pass.

What friction factor is used?

The fit for heat-exchanger tubing, f = 0.4137 Re^−0.2585 (Darcy), slightly below commercial-pipe values; f = 64/Re in laminar flow.

What do the defaults represent?

An illustrative case: Cooling water, 2 passes, U-tubes, 6 m. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 5.3.1, eqs. 5.1 to 5.5, Table 5.1, Appendix 5.A and Example 5.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.