Worked example
Example: Feedwater heater 0.5 MW/K, 400 to 440 K, steam side 450 K constant (450 to 449.9). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Cold stream heat capacity rate | 500.00 kW/K |
| Cold inlet | 126.85 °C |
| Cold outlet | 166.85 °C |
| Hot inlet | 176.85 °C |
| Hot outlet | 176.75 °C |
| Surroundings (dead state) temperature | 25.000 °C |
| Capital cost of equipment per kW of exergy (any currency) | 800.00 - |
| Annual interest (capital charge) rate | 12.000 % |
| Energy cost per kW-year (same currency) | 400.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat duty | 20.000 MW |
| Thermodynamic mean temperature, hot | 449.95 K |
| Thermodynamic mean temperature, cold | 419.68 K |
| Entropy generation | 3,205.7 W/K |
| Exergy destruction | 955.78 kW |
| Annual cost of exergy destruction | 474,068 |
Open this example in the calculator and change any input.
Formula
\(\dot S_{irr} = q\left(\frac{1}{T_{lm,c}} - \frac{1}{T_{lm,h}}\right), \quad T_{lm} = \frac{T_o - T_i}{\ln(T_o/T_i)}\)
\(\dot I = T_0\dot S_{irr}, \quad C = \dot I\,(c_{eq}r + c_q)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_c\) | Cold stream heat capacity rate | W/K |
| \(T_{c,i}\) | Cold inlet | K |
| \(T_{c,o}\) | Cold outlet | K |
| \(T_{h,i}\) | Hot inlet | K |
| \(T_{h,o}\) | Hot outlet | K |
| \(T_0\) | Surroundings (dead state) temperature | K |
| \(c_{eq}\) | Capital cost of equipment per kW of exergy (any currency) | - |
| \(r\) | Annual interest (capital charge) rate | - |
| \(c_q\) | Energy cost per kW-year (same currency) | - |
| \(q\) | Heat duty | W |
| \(T_{lm,h}\) | Thermodynamic mean temperature, hot | K |
| \(T_{lm,c}\) | Thermodynamic mean temperature, cold | K |
| \(\dot S_{irr}\) | Entropy generation | W/K |
| \(\dot I\) | Exergy destruction | W |
| \(C\) | Annual cost of exergy destruction | - |
Method and standards
Second-law (Gouy–Stodola) analysis of heat transfer.
Where it is used
- Comparing approach temperatures in heat recovery networks.
- Teaching second-law costs of heat exchange.
Common mistakes
- Using the arithmetic mean instead of the log mean of absolute temperatures.
- Using °C in the entropy terms.
Assumptions and limits
- Constant specific heats; heat transfer irreversibility only.
Questions and answers
Why does a smaller ΔT cost capital but save exergy?
Exergy destroyed falls roughly in proportion to ΔT/T², but the area needed rises as 1/ΔT; the optimum balances the two.
Why is it significant near ambient temperature?
Exergy destruction scales with T₀/T; at low absolute temperatures (refrigeration) each kelvin of approach is far more costly.
What do the defaults represent?
An illustrative case: Feedwater heater 0.5 MW/K, 400 to 440 K, steam side 450 K constant (450 to 449.9). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Shah and Sekulić, Fundamentals of Heat Exchanger Design (Wiley, 2003), sec. 11.4, eqs. 11.30, 11.55 and 11.64 and Example 11.9