Worked example
Example: Water-like batch, 0.7 m turbine at 90 rpm, coil side, steam 6,000. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Agitator and surface | Flat-blade turbine, coil, baffled, Re 2,000 to 700,000 (C 1.10) |
| Agitator diameter | 0.70000 m |
| Impeller speed | 90.000 rpm |
| Liquid density | 1,000.0 kg/m³ |
| Liquid viscosity | 1.0000 mPa·s |
| Liquid thermal conductivity | 0.60000 W/(m·K) |
| Liquid specific heat | 4.1800 kJ/(kg·K) |
| Viscosity ratio bulk to wall (1 to neglect) | 1.0000 - |
| Jacket-side coefficient | 6,000.0 W/(m²·K) |
| Wall thickness | 12.000 mm |
| Wall conductivity (stainless 16) | 16.000 W/(m·K) |
| Total fouling resistance | 2.0000e-04 m²·K/W |
Applying the formula below gives:
| Result | Value |
|---|---|
| Impeller Reynolds number | 735,000 |
| Prandtl number | 6.9667 |
| Nusselt number on agitator diameter | 9,050.8 |
| Vessel-side coefficient | 7,757.9 W/(m²·K) |
| Overall coefficient | 802.85 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(\frac{h_vd}{k_f} = C\left(\frac{\rho Nd^2}{\mu}\right)^a\left(\frac{c_p\mu}{k_f}\right)^{0.33}\left(\frac{\mu}{\mu_w}\right)^{0.14}\)
\(\frac{1}{U} = \frac{1}{h_v} + \frac{x_w}{k_w} + \frac{1}{h_j} + R_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{case}\) | Agitator and surface | - |
| \(d\) | Agitator diameter | m |
| \(N\) | Impeller speed | rad/s |
| \(\rho\) | Liquid density | kg/m³ |
| \(\mu\) | Liquid viscosity | Pa·s |
| \(k_f\) | Liquid thermal conductivity | W/(m·K) |
| \(c_p\) | Liquid specific heat | J/(kg·K) |
| \(\mu/\mu_w\) | Viscosity ratio bulk to wall (1 to neglect) | - |
| \(h_j\) | Jacket-side coefficient | W/(m²·K) |
| \(x_w\) | Wall thickness | m |
| \(k_w\) | Wall conductivity (stainless 16) | W/(m·K) |
| \(R_f\) | Total fouling resistance | m²·K/W |
| \(Re\) | Impeller Reynolds number | - |
| \(Pr\) | Prandtl number | - |
| \(Nu\) | Nusselt number on agitator diameter | - |
| \(h_v\) | Vessel-side coefficient | W/(m²·K) |
| \(U\) | Overall coefficient | W/(m²·K) |
Method and standards
Dimensionless correlation for agitated-vessel wall heat transfer.
Where it is used
- Batch reactor heating and cooling time estimates.
- Choosing agitator speed for heat removal.
Common mistakes
- Using rpm instead of revolutions per second in Re.
- Mixing constants from a vessel-diameter correlation with this agitator-diameter form.
Assumptions and limits
- Baffled vessel, turbulent agitation; constants depend on agitator and surface.
Questions and answers
Why does viscosity dominate?
The film coefficient varies roughly as μ^-0.34 through Re and Pr together, so viscous batches heat slowly; a wall-viscosity correction matters when cooling viscous liquids.
How do I get the jacket coefficient?
From the jacket type: steam condensing 5,000–10,000 W/(m²·K), water in a spiral-baffled jacket from a duct correlation, a half-pipe coil from a tube correlation.
What do the defaults represent?
An illustrative case: Water-like batch, 0.7 m turbine at 90 rpm, coil side, steam 6,000. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 12.18, eq. 12.86 and Example 12.15