FireCADCalc

Steam Turbine Exhaust Annulus Velocity and Leaving Loss

Exhaust volume flow, annulus velocity and leaving loss of a condensing turbine's last stage from exhaust flow, pressure, wetness and annulus area.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: 100 t/h, 8.5 kPa(a), x 0.9, 6 m²200 t/h, 6 kPa(a), x 0.9, 4 m² (choking)

Results

Specific volume21.361m³/kg
Exhaust volume flow1,186.7m³/s
Annulus velocity296.68m/s
Leaving loss per kg44.009kJ/kg
Leaving loss2,445.0kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 t/h, 8.5 kPa(a), x 0.9, 6 m². The inputs, in the units selected above:

InputValue
Exhaust steam flow100.00 t/h
Exhaust pressure (absolute)8.5000 kPa
Exhaust dryness fraction90.000 %
Total exhaust annulus area6.0000 m²

Applying the formula below gives:

ResultValue
Specific volume15.386 m³/kg
Exhaust volume flow427.38 m³/s
Annulus velocity71.231 m/s
Leaving loss per kg2.5369 kJ/kg
Leaving loss70.470 kW

Open this example in the calculator and change any input.

Formula

\(\dot V = \dot m\,v(p, x), \quad c = \frac{\dot V}{A}, \quad \Delta h_{LL} = \frac{c^2}{2}, \quad P_{LL} = \dot m\frac{c^2}{2}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Exhaust steam flow kg/s
\(p\) Exhaust pressure (absolute) Pa
\(x\) Exhaust dryness fraction -
\(A\) Total exhaust annulus area m²
\(v\) Specific volume m³/kg
\(\dot V\) Exhaust volume flow m³/s
\(c\) Annulus velocity m/s
\(\Delta h_{LL}\) Leaving loss per kg J/kg
\(P_{LL}\) Leaving loss W

Method and standards

The leaving loss is the kinetic energy of the steam leaving the last stage, c²/2, with the axial velocity found from the volume flow (IF97 specific volume of the wet exhaust) and the annulus area.

Where it is used

  • Turbine back pressure optimisation.
  • Last-stage selection for a site.

Common mistakes

  • Using dry saturated volume for wet exhaust.
  • Taking the annulus of one flow of a double-flow exhaust.

Assumptions and limits

  • Axial exhaust; uniform velocity; no swirl and no diffuser recovery, so the makers' leaving-loss curves differ.
  • The 300 m/s and 120 m/s warning levels are indicative, not sourced limits.

References

  • Kinetic energy of the exhaust
  • Δh = c²/2
  • with IAPWS-IF97 specific volume (Babcock & Wilcox, Steam: Its Generation and Use, 41st ed. (2005), ch. 2)

Questions and answers

What is leaving loss?

The kinetic energy of steam leaving the last blades, which the condenser cannot use; it rises with the square of annulus velocity.

Why does low back pressure stop helping?

Specific volume and so velocity rise as pressure falls; past choking, extra vacuum only adds leaving loss.

What do the defaults give?

100 t/h at 8.5 kPa(a) and 90 % dryness through 6 m²: about 430 m³/s, 71 m/s and 2.5 kJ/kg (about 70 kW) of leaving loss: low velocity for this annulus.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.