Worked example
Example: 100 t/h, 8.5 kPa(a), x 0.9, 6 m². The inputs, in the units selected above:
| Input | Value |
|---|---|
| Exhaust steam flow | 100.00 t/h |
| Exhaust pressure (absolute) | 8.5000 kPa |
| Exhaust dryness fraction | 90.000 % |
| Total exhaust annulus area | 6.0000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific volume | 15.386 m³/kg |
| Exhaust volume flow | 427.38 m³/s |
| Annulus velocity | 71.231 m/s |
| Leaving loss per kg | 2.5369 kJ/kg |
| Leaving loss | 70.470 kW |
Open this example in the calculator and change any input.
Formula
\(\dot V = \dot m\,v(p, x), \quad c = \frac{\dot V}{A}, \quad \Delta h_{LL} = \frac{c^2}{2}, \quad P_{LL} = \dot m\frac{c^2}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Exhaust steam flow | kg/s |
| \(p\) | Exhaust pressure (absolute) | Pa |
| \(x\) | Exhaust dryness fraction | - |
| \(A\) | Total exhaust annulus area | m² |
| \(v\) | Specific volume | m³/kg |
| \(\dot V\) | Exhaust volume flow | m³/s |
| \(c\) | Annulus velocity | m/s |
| \(\Delta h_{LL}\) | Leaving loss per kg | J/kg |
| \(P_{LL}\) | Leaving loss | W |
Method and standards
The leaving loss is the kinetic energy of the steam leaving the last stage, c²/2, with the axial velocity found from the volume flow (IF97 specific volume of the wet exhaust) and the annulus area.
Where it is used
- Turbine back pressure optimisation.
- Last-stage selection for a site.
Common mistakes
- Using dry saturated volume for wet exhaust.
- Taking the annulus of one flow of a double-flow exhaust.
Assumptions and limits
- Axial exhaust; uniform velocity; no swirl and no diffuser recovery, so the makers' leaving-loss curves differ.
- The 300 m/s and 120 m/s warning levels are indicative, not sourced limits.
References
- Kinetic energy of the exhaust
- Δh = c²/2
- with IAPWS-IF97 specific volume (Babcock & Wilcox, Steam: Its Generation and Use, 41st ed. (2005), ch. 2)
Questions and answers
What is leaving loss?
The kinetic energy of steam leaving the last blades, which the condenser cannot use; it rises with the square of annulus velocity.
Why does low back pressure stop helping?
Specific volume and so velocity rise as pressure falls; past choking, extra vacuum only adds leaving loss.
What do the defaults give?
100 t/h at 8.5 kPa(a) and 90 % dryness through 6 m²: about 430 m³/s, 71 m/s and 2.5 kJ/kg (about 70 kW) of leaving loss: low velocity for this annulus.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.