Worked example
Example: HP heater 12 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shell (extraction steam) pressure (absolute) | 12.000 bar |
| Feedwater in | 140.00 °C |
| Feedwater out | 185.00 °C |
| Drain leaving | 148.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saturation temperature at shell pressure | 187.96 °C |
| Terminal temperature difference T_sat − T_fw,out | 2.9646 K |
| Drain cooler approach T_d − T_fw,in | 8.0000 K |
| Feedwater temperature rise | 45.000 K |
Open this example in the calculator and change any input.
Formula
\(TTD = T_{sat}(p_s) - T_{fw,out}, \quad DCA = T_d - T_{fw,in}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_s\) | Shell (extraction steam) pressure (absolute) | Pa |
| \(T_{fw,in}\) | Feedwater in | K |
| \(T_{fw,out}\) | Feedwater out | K |
| \(T_d\) | Drain leaving | K |
| \(T_{sat}\) | Saturation temperature at shell pressure | K |
| \(TTD\) | Terminal temperature difference T_sat − T_fw,out | K |
| \(DCA\) | Drain cooler approach T_d − T_fw,in | K |
| \(\Delta T\) | Feedwater temperature rise | K |
Method and standards
Definitions.
Where it is used
- Heater performance monitoring.
- BOE examinations.
Common mistakes
- Gauge pressure for T_sat.
- Confusing TTD and DCA.
Assumptions and limits
- Steady operation.
- A negative TTD is possible with a desuperheating zone. A negative DCA, or a drain hotter than saturation, is not physical; notes flag both.
References
- TTD = T_sat(p_shell) − T_fw
- out; DCA = T_drain − T_fw
- in (definitions as in the HEI Standards for Closed Feedwater Heaters and ASME PTC 12.1, Closed Feedwater Heaters); T_sat from IAPWS-IF97
Questions and answers
12 bar(a) shell, feedwater 140 → 185 °C, drain 148 °C?
T_sat about 188 °C: TTD about 3 K, DCA 8 K, rise 45 K.
Negative TTD?
Possible with a desuperheating zone: the outlet can exceed T_sat.
High DCA?
Often a low drain level letting steam through the drain cooler.