Worked example
Example: 2.5 to 2.0 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 100.00 t/h |
| Inlet pressure (absolute) | 67.000 bar |
| Inlet temperature | 495.00 °C |
| Exhaust pressure A (absolute) | 2.5000 bar |
| Exhaust pressure B (absolute) | 2.0000 bar |
| Isentropic efficiency | 78.000 % |
| Gearbox and generator efficiency | 96.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Power at exhaust A | 16.312 MW |
| Power at exhaust B | 17.097 MW |
| Power difference B − A | 785.89 kW |
| Power per bar of exhaust pressure | 1,571.8 kW |
Open this example in the calculator and change any input.
Formula
\(P = \dot m\,\eta_s [h_1 - h(p_e, s_1)]\,\eta_g, \quad \Delta P = P_B - P_A, \quad \frac{\Delta P}{\Delta p} = \frac{P_B - P_A}{(p_{e,A} - p_{e,B})/1\ \text{bar}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Steam flow | kg/s |
| \(p_1\) | Inlet pressure (absolute) | Pa |
| \(T_1\) | Inlet temperature | K |
| \(h_1\), \(s_1\) | inlet enthalpy and entropy (IF97) | J/kg, J/(kg·K) |
| \(h(p_e, s_1)\) | isentropic exhaust enthalpy | J/kg |
| \(p_{e,A}\) | Exhaust pressure A (absolute) | Pa |
| \(p_{e,B}\) | Exhaust pressure B (absolute) | Pa |
| \(\eta_s\) | Isentropic efficiency | - |
| \(\eta_g\) | Gearbox and generator efficiency | - |
| \(P_A\) | Power at exhaust A | W |
| \(P_B\) | Power at exhaust B | W |
| \(\Delta P\) | Power difference B − A | W |
| \(\Delta P/\Delta p\) | Power per bar of exhaust pressure | W |
Method and standards
Expansion from the inlet state to each exhaust pressure at the inlet entropy (IAPWS-IF97), scaled by the isentropic efficiency and the gearbox and generator efficiency; the difference is expressed per bar of exhaust pressure. A note appears if an actual exhaust state is wet.
Where it is used
- Exhaust pressure setting.
- Process–power optimisation.
Common mistakes
- Gauge exhaust pressure.
Assumptions and limits
- Constant efficiency.
- The inlet must be superheated (or supercritical) steam; an inlet below saturation is rejected.
References
- Isentropic expansion with efficiency; IAPWS-IF97
Questions and answers
Why is exhaust pressure a trade-off in sugar mills?
Lower exhaust gives more power but a smaller temperature difference for the evaporators and pans.
How much per bar?
Run the calculator: typically several per cent of turbine power per bar near 2 bar(a).
Same efficiency at both?
Nearly, for small changes; large changes alter the machine's efficiency.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.