Back-Pressure Turbine: Power vs Exhaust Pressure

Power of a back-pressure turbine at two exhaust pressures for the same inlet steam (IF97), and the power gained per bar lower exhaust pressure.

Process steam and utilitiesSugar mill and cogenerationDistillery and ethanolPulp and paperIAPWS-IF97 (water and steam)Steam turbine

Inputs

Examples: 2.5 to 2.0 bar(a)4 to 3.5 bar(a)

Results

Lower exhaust pressure gives power but less evaporator temperature difference in the process: balance the two.

Power at exhaust A16.312MW
Power at exhaust B17.097MW
Power difference B − A785.89kW
Power per bar of exhaust pressure1,571.8kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2.5 to 2.0 bar(a). The inputs, in the units selected above:

InputValue
Steam flow100.00 t/h
Inlet pressure (absolute)67.000 bar
Inlet temperature495.00 °C
Exhaust pressure A (absolute)2.5000 bar
Exhaust pressure B (absolute)2.0000 bar
Isentropic efficiency78.000 %
Gearbox and generator efficiency96.000 %

Applying the formula below gives:

ResultValue
Power at exhaust A16.312 MW
Power at exhaust B17.097 MW
Power difference B − A785.89 kW
Power per bar of exhaust pressure1,571.8 kW

Open this example in the calculator and change any input.

Formula

\(P = \dot m\,\eta_s [h_1 - h(p_e, s_1)]\,\eta_g, \quad \Delta P = P_B - P_A, \quad \frac{\Delta P}{\Delta p} = \frac{P_B - P_A}{(p_{e,A} - p_{e,B})/1\ \text{bar}}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Steam flow kg/s
\(p_1\) Inlet pressure (absolute) Pa
\(T_1\) Inlet temperature K
\(h_1\), \(s_1\) inlet enthalpy and entropy (IF97) J/kg, J/(kg·K)
\(h(p_e, s_1)\) isentropic exhaust enthalpy J/kg
\(p_{e,A}\) Exhaust pressure A (absolute) Pa
\(p_{e,B}\) Exhaust pressure B (absolute) Pa
\(\eta_s\) Isentropic efficiency -
\(\eta_g\) Gearbox and generator efficiency -
\(P_A\) Power at exhaust A W
\(P_B\) Power at exhaust B W
\(\Delta P\) Power difference B − A W
\(\Delta P/\Delta p\) Power per bar of exhaust pressure W

Method and standards

Expansion from the inlet state to each exhaust pressure at the inlet entropy (IAPWS-IF97), scaled by the isentropic efficiency and the gearbox and generator efficiency; the difference is expressed per bar of exhaust pressure. A note appears if an actual exhaust state is wet.

Where it is used

  • Exhaust pressure setting.
  • Process–power optimisation.

Common mistakes

  • Gauge exhaust pressure.

Assumptions and limits

  • Constant efficiency.
  • The inlet must be superheated (or supercritical) steam; an inlet below saturation is rejected.

References

  • Isentropic expansion with efficiency; IAPWS-IF97

Questions and answers

Why is exhaust pressure a trade-off in sugar mills?

Lower exhaust gives more power but a smaller temperature difference for the evaporators and pans.

How much per bar?

Run the calculator: typically several per cent of turbine power per bar near 2 bar(a).

Same efficiency at both?

Nearly, for small changes; large changes alter the machine's efficiency.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.