FireCADCalc

Mean Beam Length of a Furnace or Gas Space

Mean beam length of a gas volume for radiation to its whole boundary (3.6 V/A, Hottel) and the optically thin limit (4 V/A), for gas emissivity look-ups.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBurner and furnace

Inputs

Examples: Furnace 450 m3Cube 1 m

Results

Multiply the beam length by the partial pressures of CO₂ and H₂O, in the units of your chart or correlation (atm·m, atm·ft or bar·m), to read the gas emissivity.

Mean beam length 3.6 V/A0.60000m
Optically thin limit 4 V/A0.66667m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Furnace 450 m3. The inputs, in the units selected above:

InputValue
Gas volume450.00 m³
Bounding surface area420.00 m²

Applying the formula below gives:

ResultValue
Mean beam length 3.6 V/A3.8571 m
Optically thin limit 4 V/A4.2857 m

Open this example in the calculator and change any input.

Formula

\(L_e = 3.6\frac{V}{A}, \quad L_0 = 4\frac{V}{A}\)

Variables

Symbol Meaning SI unit
\(V\) Gas volume m³
\(A\) Bounding surface area m²
\(L_e\) Mean beam length 3.6 V/A m
\(L_0\) Optically thin limit 4 V/A m

Method and standards

Hottel's whole-enclosure mean beam length, 3.6 V/A, an average over the usual optical depths, and the optically thin limit 4 V/A.

Where it is used

  • Furnace and radiant-section design.
  • Gas emissivity estimates.

Common mistakes

  • Tube surface area used instead of enclosure area.

Assumptions and limits

  • Whole-enclosure average. For particular shapes and for radiation to one part of the boundary (tube banks, long cylinders, radiation to the base of a cylinder), the tabulated mean beam lengths in Hottel and Sarofim or Incropera differ from 3.6 V/A: use them there.
  • V and A must describe a real enclosure: V/A cannot exceed that of a sphere, √(A/36π).

References

  • Hottel: mean beam length L_e ≈ 3.6 V/A for radiation to the whole enclosure; optically thin limit 4 V/A (Hottel and Sarofim, Radiative Transfer, McGraw-Hill, 1967; Incropera, Fundamentals of Heat and Mass Transfer)

Questions and answers

What is the mean beam length?

The radius of a gas hemisphere that radiates to its base like the real gas volume radiates to its walls.

Why 3.6 and not 4?

4 V/A is exact only for a very thin gas; 3.6 V/A is the usual average for real optical depths.

What do I do with it?

Multiply by the CO₂ and H₂O partial pressures, in the chart's units (atm·m, atm·ft or bar·m), to find the gas emissivity.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.