Worked example
Example: Furnace 450 m3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas volume | 450.00 m³ |
| Bounding surface area | 420.00 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mean beam length 3.6 V/A | 3.8571 m |
| Optically thin limit 4 V/A | 4.2857 m |
Open this example in the calculator and change any input.
Formula
\(L_e = 3.6\frac{V}{A}, \quad L_0 = 4\frac{V}{A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Gas volume | m³ |
| \(A\) | Bounding surface area | m² |
| \(L_e\) | Mean beam length 3.6 V/A | m |
| \(L_0\) | Optically thin limit 4 V/A | m |
Method and standards
Hottel's whole-enclosure mean beam length, 3.6 V/A, an average over the usual optical depths, and the optically thin limit 4 V/A.
Where it is used
- Furnace and radiant-section design.
- Gas emissivity estimates.
Common mistakes
- Tube surface area used instead of enclosure area.
Assumptions and limits
- Whole-enclosure average. For particular shapes and for radiation to one part of the boundary (tube banks, long cylinders, radiation to the base of a cylinder), the tabulated mean beam lengths in Hottel and Sarofim or Incropera differ from 3.6 V/A: use them there.
- V and A must describe a real enclosure: V/A cannot exceed that of a sphere, √(A/36π).
References
- Hottel: mean beam length L_e ≈ 3.6 V/A for radiation to the whole enclosure; optically thin limit 4 V/A (Hottel and Sarofim, Radiative Transfer, McGraw-Hill, 1967; Incropera, Fundamentals of Heat and Mass Transfer)
Questions and answers
What is the mean beam length?
The radius of a gas hemisphere that radiates to its base like the real gas volume radiates to its walls.
Why 3.6 and not 4?
4 V/A is exact only for a very thin gas; 3.6 V/A is the usual average for real optical depths.
What do I do with it?
Multiply by the CO₂ and H₂O partial pressures, in the chart's units (atm·m, atm·ft or bar·m), to find the gas emissivity.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.