Worked example
Example: WHB pass 800 °C gas. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow (all tubes) | 20.000 t/h |
| Tubes in the pass | 120.00 - |
| Tube inside diameter | 50.800 mm |
| Tube length | 5.0000 m |
| Gas inlet temperature | 800.00 °C |
| Water (saturation) temperature | 184.00 °C |
| Target gas outlet temperature | 250.00 °C |
| Gas specific heat | 1.1500 kJ/(kg·K) |
| Gas viscosity (mean) | 3.2000e-05 Pa·s |
| Gas thermal conductivity (mean) | 0.050000 W/(m·K) |
| Water vapour in the gas, volume fraction (= partial pressure, atm) | 12.000 % |
| CO₂ + SO₂ in the gas, volume fraction (= partial pressure, atm) | 10.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reynolds number | 36,261 |
| Convective coefficient (Dittus–Boelter, cooling) | 91.717 W/(m²·K) |
| Non-luminous radiation coefficient at the gas inlet | 6.3986 W/(m²·K) |
| Non-luminous radiation coefficient at the gas outlet | 2.4144 W/(m²·K) |
| Gas outlet temperature | 331.22 °C |
| Duty | 2,995.0 kW |
| Tube length for the target outlet | 7.8516 m |
Open this example in the calculator and change any input.
Formula
\(Nu = \frac{h_c d_i}{k} = 0.023 Re^{0.8} Pr^{0.3}, \quad h_N = \sigma \varepsilon_g \frac{T^4 - T_s^4}{T - T_s}\)
\(\varepsilon_g = 0.9\left(1 - e^{-K d_i}\right), \quad K = \frac{(0.8 + 1.6 p_w)(1 - 0.38\,T/1000)(p_c + p_w)}{\sqrt{(p_c + p_w) d_i}}\)
\(\dot m_1 c_p \frac{dT}{dx} = -(h_c + h_N)\,\pi d_i (T - T_s), \quad L_t = \frac{\dot m_1 c_p}{\pi d_i}\int_{T_t}^{T_{in}} \frac{dT}{(h_c + h_N)(T - T_s)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | Gas flow (all tubes) | kg/s |
| \(\dot m_1\) | Gas flow per tube, \(\dot m_g/n\) | kg/s |
| \(n\) | Tubes in the pass | - |
| \(d_i\) | Tube inside diameter, also the radiation beam length | m |
| \(L\) | Tube length | m |
| \(x\) | Distance along the tube | m |
| \(T\) | Local gas temperature | K |
| \(T_{in}\) | Gas inlet temperature | K |
| \(T_s\) | Water (saturation) temperature, taken as the wall temperature | K |
| \(T_{target}\) | Target gas outlet temperature (\(T_t\) in the formula) | K |
| \(c_p\) | Gas specific heat | J/(kg·K) |
| \(\mu\) | Gas viscosity (mean) | Pa·s |
| \(k\) | Gas thermal conductivity (mean) | W/(m·K) |
| \(p_w\) | Water vapour in the gas, volume fraction (partial pressure in atm) | - |
| \(p_c\) | CO₂ + SO₂ in the gas, volume fraction (partial pressure in atm) | - |
| \(K\) | Attenuation factor of the gas | 1/m |
| \(\varepsilon_g\) | Gas emissivity | - |
| \(\sigma\) | Stefan–Boltzmann constant | W/(m²·K⁴) |
| \(Re\) | Reynolds number | - |
| \(Pr\) | Prandtl number | - |
| \(Nu\) | Nusselt number | - |
| \(h_c\) | Convective coefficient (Dittus–Boelter, cooling) | W/(m²·K) |
| \(h_N\) | Non-luminous radiation coefficient | W/(m²·K) |
| \(h_{N,in}\) | \(h_N\) at the gas inlet | W/(m²·K) |
| \(h_{N,out}\) | \(h_N\) at the gas outlet | W/(m²·K) |
| \(T_{out}\) | Gas outlet temperature | K |
| \(\dot Q\) | Duty | W |
| \(L_t\) | Tube length for the target outlet | m |
Method and standards
Dittus–Boelter convection inside the tubes plus non-luminous radiation from the CO₂ and H₂O in the gas, by Ganapathy's equations (Industrial Boilers and Heat Recovery Steam Generators, 2003, Q8.07b, Eqs. 26, 28a and 28b), with the beam length equal to the tube bore as Ganapathy gives for fire-tube boilers. The radiation coefficient changes with the gas temperature, so the energy balance is integrated along the tube with the wall at the water saturation temperature.
Where it is used
- Fire-tube and waste-heat boiler design.
- Exit temperature checks.
Common mistakes
- Total gas flow used per tube.
- Leaving out gas radiation at high inlet temperatures: it can be 5–15 % of the convective coefficient in the first pass.
Assumptions and limits
- Turbulent flow; constant convective properties.
- Non-luminous radiation only. The gas is taken near atmospheric pressure, so the volume fractions equal the partial pressures in atm. Soot or ash would add luminous radiation, which is not included. Enter 0 for both gas fractions to see convection alone.
- Wall at the water saturation temperature; tube-wall, scale and soot resistances are neglected.
References
- Dittus–Boelter Nu = 0.023 Re^0.8 Pr^0.3 (cooling); constant wall temperature T_out = T_s + (T_in − T_s) e^{−NTU} (Incropera); non-luminous gas radiation
- Ganapathy
- Industrial Boilers and HRSGs (2003)
- Q8.07b
- Eqs. 26
- 28a
- 28b
Questions and answers
Why constant water temperature?
The water side boils at saturation, so the tube wall stays near T_sat.
Where do gas properties come from?
Mean values at the average gas temperature; flue gas is close to air with more water vapour.
Longer tubes?
Exit temperature approaches the water temperature exponentially: the last degrees cost the most length.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.