Worked example
Example: 30 t/h steam. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Relieving flow | 30.000 t/h |
| Exit velocity | 450.00 m/s |
| Exit static pressure (absolute) | 4.0000 bar |
| Atmospheric pressure | 1.0132 bar |
| Outlet bore | 150.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Outlet area | 0.017671 m² |
| Momentum term | 3.7500 kN |
| Pressure term | 5.2780 kN |
| Reaction force | 9.0280 kN |
Open this example in the calculator and change any input.
Formula
\(F = \dot m v_e + (p_e - p_a) A_e\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Relieving flow | kg/s |
| \(v_e\) | Exit velocity | m/s |
| \(p_e\) | Exit static pressure (absolute) | Pa |
| \(p_a\) | Atmospheric pressure | Pa |
| \(d_e\) | Outlet bore | m |
| \(A_e\) | Outlet area | m² |
| \(F_m\) | Momentum term | N |
| \(F_p\) | Pressure term | N |
| \(F\) | Reaction force | N |
Method and standards
Steady momentum balance on a control volume around the open outlet: the reaction is the momentum flux of the jet plus the excess of exit static pressure over atmospheric acting on the outlet area. A note gives the exit density implied by continuity (ṁ = ρ v A) and flags it when it exceeds dry saturated steam at the exit pressure.
Where it is used
- Safety valve exhaust support design.
Common mistakes
- Gauge exit pressure with atmospheric again subtracted.
Assumptions and limits
- Steady discharge.
- Flow, velocity, exit pressure and bore are your inputs and are not solved together; check them against the valve's choked-flow data. Only the continuity note links them.
References
- Momentum balance F = ṁ v_e + (p_e − p_a) A_e (the same physics as published reaction-force methods; no code tables)
Questions and answers
Why the pressure term?
Choked flow leaves the pipe above atmospheric pressure, which pushes on the open area.
Where to get exit velocity?
From the critical (choked) flow at the exit: the exit velocity is then the sonic velocity of the steam at the exit pressure and temperature.
Supports?
Add a dynamic load factor for sudden opening.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.