Boiler Drum Flash Steam on Pressure Drop (Swell)

Steam flashed from the boiler water when drum pressure falls, its volume and the average steam surge: the cause of drum level swell on a sudden load increase.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 10 t of water, 45 to 40 bar(a) in 60 s40 t, 105 to 95 bar(a) in 120 s3 t, 17.5 to 14 bar(a) in 30 s

Results

The bubbles swell the drum level before they escape; how much they lift it depends on the drum and riser design, so the drum level control must ride through the swell rather than cut the feed.

Steam flashed from the water1,283.1kg
Average extra steam generation38,494kg/h
Volume of that steam at the lower pressure24.639m³
Flash fraction of the water3.2078%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t of water, 45 to 40 bar(a) in 60 s. The inputs, in the units selected above:

InputValue
Water in drum, downcomers and risers10.000 t
Drum pressure before (absolute)45.000 bar
Drum pressure after (absolute)40.000 bar
Time over which the pressure falls60.000 s

Applying the formula below gives:

ResultValue
Steam flashed from the water202.61 kg
Average extra steam generation12,157 kg/h
Volume of that steam at the lower pressure10.085 m³
Flash fraction of the water2.0261 %

Open this example in the calculator and change any input.

Formula

\(x = \frac{h_f(p_1) - h_f(p_2)}{h_g(p_2) - h_f(p_2)} \qquad m_{fl} = M_w\,x \qquad V_{fl} = m_{fl}\,v_g(p_2) \qquad \dot m_{fl} = \frac{m_{fl}}{\Delta t}\)

Variables

Symbol Meaning SI unit
\(M_w\) water in drum, downcomers and risers kg
\(p_1\) drum pressure before, absolute Pa
\(p_2\) drum pressure after, absolute Pa
\(\Delta t\) time of the pressure fall s
\(m_{fl}\) steam flashed kg
\(\dot m_{fl}\) average extra steam generation kg/s
\(V_{fl}\) volume of the flashed steam m³
\(x\) flash fraction –
\(h_f\), \(h_g\) saturated liquid and vapour enthalpy (IF97) J/kg
\(v_g\) saturated vapour specific volume (IF97) m³/kg

Method and standards

Energy balance of saturated water cooling to the new saturation temperature, with saturation properties from FireCAD's IAPWS-IF97. Heat released by the steel is neglected, so the flash is slightly understated.

Where it is used

  • Explaining and sizing for drum level swell on load swings.
  • Setting drum level alarm margins and control tuning.
  • Studying load rejection and sudden steam demand.

Common mistakes

  • Treating the swell as extra water and cutting the feed.
  • Using gauge pressures.
  • Counting only the drum water and not the risers.

Assumptions and limits

  • Water saturated at the starting pressure; no heat from the metal or the fire during the drop; the level rise itself depends on the drum and riser design and is not calculated.
  • One-step flash on the initial water mass; for a large pressure drop a stepwise balance, in which the water mass falls as it flashes, gives slightly less steam.

References

  • IAPWS R7-97(2012) IF97
  • first law of thermodynamics

Questions and answers

Why does drum level rise when steam demand jumps?

The pressure falls and the saturated water flashes. 10 t of water dropping from 45 to 40 bar(a) flashes 2.0 %, 203 kg of steam taking 10 m³ at 40 bar(a); over a minute that is 3.4 kg/s, about 12 t/h of extra steam, and its bubbles lift the level.

Why is it called swell and shrink?

Swell is the rise on a pressure drop; shrink is the fall when pressure recovers or cold feedwater is added and the bubbles collapse.

How should the level control handle it?

With three-element control (level, steam flow, feed flow), so the feed valve does not close on a false high level and then starve the drum.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.