Worked example
Example: 10 t of water, 45 to 40 bar(a) in 60 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water in drum, downcomers and risers | 10.000 t |
| Drum pressure before (absolute) | 45.000 bar |
| Drum pressure after (absolute) | 40.000 bar |
| Time over which the pressure falls | 60.000 s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam flashed from the water | 202.61 kg |
| Average extra steam generation | 12,157 kg/h |
| Volume of that steam at the lower pressure | 10.085 m³ |
| Flash fraction of the water | 2.0261 % |
Open this example in the calculator and change any input.
Formula
\(x = \frac{h_f(p_1) - h_f(p_2)}{h_g(p_2) - h_f(p_2)} \qquad m_{fl} = M_w\,x \qquad V_{fl} = m_{fl}\,v_g(p_2) \qquad \dot m_{fl} = \frac{m_{fl}}{\Delta t}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M_w\) | water in drum, downcomers and risers | kg |
| \(p_1\) | drum pressure before, absolute | Pa |
| \(p_2\) | drum pressure after, absolute | Pa |
| \(\Delta t\) | time of the pressure fall | s |
| \(m_{fl}\) | steam flashed | kg |
| \(\dot m_{fl}\) | average extra steam generation | kg/s |
| \(V_{fl}\) | volume of the flashed steam | m³ |
| \(x\) | flash fraction | – |
| \(h_f\), \(h_g\) | saturated liquid and vapour enthalpy (IF97) | J/kg |
| \(v_g\) | saturated vapour specific volume (IF97) | m³/kg |
Method and standards
Energy balance of saturated water cooling to the new saturation temperature, with saturation properties from FireCAD's IAPWS-IF97. Heat released by the steel is neglected, so the flash is slightly understated.
Where it is used
- Explaining and sizing for drum level swell on load swings.
- Setting drum level alarm margins and control tuning.
- Studying load rejection and sudden steam demand.
Common mistakes
- Treating the swell as extra water and cutting the feed.
- Using gauge pressures.
- Counting only the drum water and not the risers.
Assumptions and limits
- Water saturated at the starting pressure; no heat from the metal or the fire during the drop; the level rise itself depends on the drum and riser design and is not calculated.
- One-step flash on the initial water mass; for a large pressure drop a stepwise balance, in which the water mass falls as it flashes, gives slightly less steam.
References
- IAPWS R7-97(2012) IF97
- first law of thermodynamics
Questions and answers
Why does drum level rise when steam demand jumps?
The pressure falls and the saturated water flashes. 10 t of water dropping from 45 to 40 bar(a) flashes 2.0 %, 203 kg of steam taking 10 m³ at 40 bar(a); over a minute that is 3.4 kg/s, about 12 t/h of extra steam, and its bubbles lift the level.
Why is it called swell and shrink?
Swell is the rise on a pressure drop; shrink is the fall when pressure recovers or cold feedwater is added and the bubbles collapse.
How should the level control handle it?
With three-element control (level, steam flow, feed flow), so the feed valve does not close on a false high level and then starve the drum.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.