FireCADCalc

Massecuite Head and Boiling Temperature in a Pan

Rise of boiling temperature with depth of massecuite in a vacuum pan from the pan pressure, head and density (IF97), with the liquor's boiling-point elevation.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: 1.5 m of A massecuite at 16 kPaC strike 2 m at 13 kPa

Hugot: about 1.47 hot; 0.15 kg/cm² of head per metre.

Results

Hugot keeps massecuite no more than about 1.5 m above the top tube plate with natural circulation: below that depth it hardly boils.

The elevation e is Hugot's formula for pure sucrose solutions: impure mother liquors of B and C massecuites boil higher, so e is low for them.

Pressure at that depth42.420kPa
Water saturation temperature at the surface51.035°C
Water saturation temperature at depth77.275°C
Rise due to the head26.240K
Boiling-point elevation of the liquor11.442K
Boiling temperature at that depth88.718°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1.5 m of A massecuite at 16 kPa. The inputs, in the units selected above:

InputValue
Absolute pressure in the pan16.000 kPa
Depth of massecuite above the point1.5000 m
Massecuite density1,470.0 kg/m³
Brix of the mother liquor80.000 %
Barometric pressure101.33 kPa

Applying the formula below gives:

ResultValue
Pressure at that depth37.624 kPa
Water saturation temperature at the surface55.314 °C
Water saturation temperature at depth74.392 °C
Rise due to the head19.078 K
Boiling-point elevation of the liquor7.9948 K
Boiling temperature at that depth82.387 °C

Open this example in the calculator and change any input.

Formula

\(p_h = p + \rho_m g h, \quad \Delta T_h = T_s(p_h) - T_s(p), \quad T_b = T_s(p_h) + e(B)\)

Variables

Symbol Meaning SI unit
\(p\) Absolute pressure in the pan Pa
\(h\) Depth of massecuite above the point m
\(\rho_m\) Massecuite density kg/m³
\(B\) Brix of the mother liquor -
\(p_a\) Barometric pressure Pa
\(p_h\) Pressure at that depth Pa
\(T_s\) Water saturation temperature at the surface K
\(T_h\) Water saturation temperature at depth K
\(\Delta T_h\) Rise due to the head K
\(e\) Boiling-point elevation of the liquor K
\(T_b\) Boiling temperature at that depth K

Method and standards

Hydrostatics with IF97 and Hugot's boiling-point elevation.

Where it is used

  • Pan design and strike height.
  • Explaining slow boiling of tall strikes.

Common mistakes

  • Using water density.
  • Forgetting the elevation of the liquor.

Assumptions and limits

  • Liquid column without vapour (conservative).
  • The boiling-point elevation is Hugot's formula for pure sucrose solutions, with no purity input: for low-purity mother liquors (B and C massecuites) the true elevation is higher.
  • The vacuum in the elevation formula is the barometric pressure entered less the pressure at depth, in cmHg.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 33
  • hydrostatic pressure in pans
  • p. 647
  • and boiling-point elevation
  • ch. 32
  • Saturation temperatures from IAPWS-IF97

Questions and answers

Why does the head matter so much in pans?

At 16 kPa absolute a metre of massecuite adds about 14 kPa: the boiling point at the tubes rises by 15–20 °C.

What does it do to boiling?

The temperature difference to the steam shrinks, so the lower part of a tall strike hardly evaporates.

Why add the elevation?

Massecuite liquor at 80 brix boils several degrees above water at the same pressure.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.