Worked example
Example: Hugot example: 70 -> air 30, D 1.8, m 3.33. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Massecuite temperature at the start | 70.000 °C |
| Air temperature | 30.000 °C |
| Crystalliser width (diameter) | 1.8000 m |
| Length / width | 3.3300 - |
| Heat-transfer coefficient to air | 8.1410 W/(m²·K) |
| Massecuite specific heat | 1.8422 kJ/(kg·K) |
| Massecuite density | 1,500.0 kg/m³ |
| Time | 24.000 h |
| Target temperature | 45.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cooling surface / volume | 2.5559 1/m |
| Massecuite temperature after the time | 50.870 °C |
| Time to the target temperature | 36.182 h |
Open this example in the calculator and change any input.
Formula
\(\frac{S}{V} = \frac{2(1 + 2m)}{mD}, \quad T = \theta + (T_0 - \theta)\exp\left(-\frac{k}{d_m c}\frac{S}{V}t\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_0\) | Massecuite temperature at the start | K |
| \(\theta\) | Air temperature | K |
| \(D\) | Crystalliser width (diameter) | m |
| \(m\) | Length / width | - |
| \(k\) | Heat-transfer coefficient to air | W/(m²·K) |
| \(c\) | Massecuite specific heat | J/(kg·K) |
| \(d_m\) | Massecuite density | kg/m³ |
| \(t\) | Time | s |
| \(T^*\) | Target temperature | K |
| \(S/V\) | Cooling surface / volume (per m) | 1/m |
| \(T\) | Massecuite temperature after the time | K |
| \(t^*\) | Time to the target temperature | s |
Method and standards
Hugot's lumped cooling model of a U-trough.
Where it is used
- Estimating cooling time.
- Judging whether water cooling is needed.
Common mistakes
- Using hot massecuite density for cold.
- Forgetting the ends in S/V for short troughs.
Assumptions and limits
- Well-mixed massecuite; constant coefficient.
- If the target temperature is not between the air and starting temperatures, the time to it is left out with a note; a note also appears when the starting cooling rate exceeds about 1 °C/h.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 34
- cooling in air-cooled crystallisers
- eqns 34.6–34.13
- pp. 729–731
Questions and answers
Why so slow?
The surface per volume of a large trough is small and the coefficient to air low (Hugot about 7 kcal/(m²·h·°C)).
What limits cooling rate?
Too fast cooling raises supersaturation and forms false grain; Hugot keeps it to about 1 °C/h.
Why water cooling?
To shorten the time: water-cooled units reach 40 °C in 12–20 h.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.