Worked example
Example: 40 m3 pan, 1.2 m impeller. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pan working volume | 40.000 m³ |
| Impeller diameter | 1.2000 m |
| Impeller speed | 80.000 rpm |
| Installed power per m³ | 2.3000 kW/m³ |
| Average power per m³ | 1.0000 kW/m³ |
| Strike time | 3.0000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Installed power | 92.000 kW |
| Average power | 40.000 kW |
| Tip speed | 5.0265 m/s |
| Energy per strike | 120.00 kWh |
Open this example in the calculator and change any input.
Formula
\(P_i = e_i V, \quad P_a = e_a V, \quad v_t = \pi D_i n, \quad E = P_a t\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Pan working volume | m³ |
| \(D_i\) | Impeller diameter | m |
| \(n\) | Impeller speed | 1/s |
| \(e_i\) | Installed power per m³ | W/m³ |
| \(e_a\) | Average power per m³ | W/m³ |
| \(t\) | Strike time | s |
| \(P_i\) | Installed power | W |
| \(P_a\) | Average power | W |
| \(v_t\) | Tip speed | m/s |
| \(E\) | Energy per strike | J |
Method and standards
Hugot's specific powers.
Where it is used
- Specifying circulators.
- Energy budgets.
Common mistakes
- Using installed power as consumption.
- Too high a tip speed on C strikes.
Assumptions and limits
- Hugot's specific figures. He also gives a peak of about 1.9 kW/m³; the page shows installed and average power only.
- The tip speed is compared with Hugot's 3.5–7.5 m/s range.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 33
- mechanical circulation
- pp. 707–710
Questions and answers
Why add a circulator?
Low-grade massecuites circulate poorly; a stirrer keeps evaporation up and shortens strikes.
How efficient is it?
Hugot: about 7 % hydraulic efficiency (11 % semi-axial): most power becomes heat in the massecuite.
Which speed?
Slower for viscous low-grade strikes, to limit power and crystal damage.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.