Worked example
Example: Hugot example: A batch, B and C continuous. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 100.00 t/h |
| A massecuite per tonne cane | 140.00 L/t |
| B massecuite per tonne cane | 54.000 L/t |
| C massecuite per tonne cane | 36.000 L/t |
| Massecuite density | 1,470.0 kg/m³ |
| Steam per kg A massecuite | 0.27500 - |
| Steam per kg B massecuite | 0.30000 - |
| Steam per kg C massecuite | 0.36000 - |
| Boiling method, A massecuite | Batch pans (1.5) |
| Boiling method, B massecuite | Continuous pans (1.2) |
| Boiling method, C massecuite | Continuous pans (1.2) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam for A per tonne cane | 84.892 kg/t |
| Steam for B per tonne cane | 28.577 kg/t |
| Steam for C per tonne cane | 22.861 kg/t |
| Total per tonne cane | 136.33 kg/t |
| Pan steam | 13.633 t/h |
Open this example in the calculator and change any input.
Formula
\(s_i = v_i\,\rho_m\,k_i\,m_i, \quad s = s_A + s_B + s_C, \quad \dot m_s = s A\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(v_A\) | A massecuite per tonne cane | m³/kg |
| \(v_B\) | B massecuite per tonne cane | m³/kg |
| \(v_C\) | C massecuite per tonne cane | m³/kg |
| \(\rho_m\) | Massecuite density | kg/m³ |
| \(k_A\) | Steam per kg A massecuite | - |
| \(k_B\) | Steam per kg B massecuite | - |
| \(k_C\) | Steam per kg C massecuite | - |
| \(m_A\) | Boiling method, A massecuite | - |
| \(m_B\) | Boiling method, B massecuite | - |
| \(m_C\) | Boiling method, C massecuite | - |
| \(s_A\) | Steam for A per tonne cane | kg/kg |
| \(s_B\) | Steam for B per tonne cane | kg/kg |
| \(s_C\) | Steam for C per tonne cane | kg/kg |
| \(s\) | Total per tonne cane | kg/kg |
| \(\dot m_s\) | Pan steam | kg/s |
Method and standards
Hugot's eqn 33.29 per massecuite.
Where it is used
- Factory steam balances.
- Comparing batch and continuous pans.
Common mistakes
- Entering massecuite in t/t cane as L/kg.
- Leaving out the jigger steam.
Assumptions and limits
- Steam at pan calandria conditions. Hugot's coefficients are kg of heating steam or vapour per kg of massecuite; the page does not correct them for the steam pressure.
- The method factor is 1.2 for continuous pans, 1.5 for batch pans and 2.25 for batch pans that also use jigger steam (live steam blown into the bottom of the pan to help circulation).
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 33
- eqn 33.29 and example
- pp. 664–667
Questions and answers
Where do the coefficients come from?
Hugot: kilograms of steam per kilogram of massecuite, rising from A to C because low grades are boiled from thinner, poorer feeds and take longer.
Why 1.5 for batch pans?
Batch boiling wastes steam in steaming out, graining and part-load periods; continuous pans need about 1.2.
Typical totals?
Literature figures in Hugot run from 115 to 170 kg/t cane.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.