FireCADCalc

Vacuum Pan Surface, Volume and Footing

Heating surface to volume ratio, Hugot's volume to diameter rule (V/Δ² = 1.9), the diameter it suggests and the footing (graining) volume of a vacuum pan.

Sugar mill and cogeneration

Inputs

Examples: 30 m3 calandria pan60 m3 pan

Hugot: 24–40 % of working capacity, generally not above 30 %.

Results

S/V = 6.0 m²/m³ is in the range for calandria pans on exhaust.

Hugot's S/V: coils on live steam 3.9–4.6; calandria on exhaust 4.9–6.6; on bled vapour 6.6–7.2 m²/m³; refined sugar pans up to about 10.

Surface / volume (m²/m³)6.0000
Volume / diameter² (Hugot 1.9)1.8750m
Diameter for 1.9 m³/m²3.9736m
Graining volume9.0000m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 m3 calandria pan. The inputs, in the units selected above:

InputValue
Working volume30.000 m³
Heating surface180.00 m²
Pan diameter4.0000 m
Graining (footing) volume share30.000 %

Applying the formula below gives:

ResultValue
Surface / volume (m²/m³)6.0000
Volume / diameter² (Hugot 1.9)1.8750 m
Diameter for 1.9 m³/m²3.9736 m
Graining volume9.0000 m³

Open this example in the calculator and change any input.

Formula

\(\frac{S}{V}, \quad \frac{V}{\Delta^2} \approx 1.9\ \mathrm m, \quad \Delta_H = \sqrt{V/1.9}, \quad V_g = \phi_g V\)

Variables

Symbol Meaning SI unit
\(V\) Working volume m³
\(S\) Heating surface m²
\(\Delta\) Pan diameter m
\(\phi_g\) Graining (footing) volume share -
\(S/V\) Surface / volume (m²/m³) 1/m
\(V/\Delta^2\) Volume / diameter² (Hugot 1.9) m
\(\Delta_H\) Diameter for 1.9 m³/m² m
\(V_g\) Graining volume m³

Method and standards

Hugot's proportions.

Where it is used

  • Pan selection.
  • Checking pan proportions.

Common mistakes

  • Using total instead of working volume.
  • Comparing S/V of coil and calandria pans directly.

Assumptions and limits

  • Normal massecuite heights.
  • S/V is in m²/m³ (shown as a plain number) and is compared with Hugot's ranges in the note.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 33
  • eqns 33.15 and 33.30 and Table 33.10
  • pp. 653 and 667–669

Questions and answers

Why does S/V matter?

More surface per volume boils faster; low-temperature vapour needs more surface than live steam for the same rate.

Why limit the graining volume?

Too small a footing covers the tubes poorly; too large wastes pan capacity.

Is 1.9 m³/m² a rule?

Hugot's guide for the normal height of massecuite over the calandria.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.