Worked example
Example: 8 m3/h C massecuite 40 -> 52. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Massecuite flow | 8.0000 m³/h |
| Massecuite density | 1,500.0 kg/m³ |
| Massecuite specific heat | 1.7585 kJ/(kg·K) |
| Temperature in | 40.000 °C |
| Temperature out | 52.000 °C |
| Coil area per m³/h of massecuite | 32.500 - |
| Supply voltage | 400.00 V |
| Power factor | 100.00 % |
| Outer / inner diameter of the annulus | 1.7674 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reheating power | 70.338 kW |
| Water coil area | 260.00 m² |
| Mean conductance 6.5(T − 30) µS/cm | 104.00 |
| Electric heater active length | 3.8476 m |
Open this example in the calculator and change any input.
Formula
\(P = Q d c (t - t_0), \quad A_c = a_c Q, \quad k = 6.5(T - 30), \quad L = 3.68\times10^6\frac{P\log(D/d)}{kV^2\cos\varphi}\ [P\ \mathrm{kW}]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Massecuite flow | m³/s |
| \(d\) | Massecuite density | kg/m³ |
| \(c\) | Massecuite specific heat | J/(kg·K) |
| \(t_0\) | Temperature in | K |
| \(t\) | Temperature out | K |
| \(a_c\) | Coil area per m³/h of massecuite | - |
| \(V\) | Supply voltage | V |
| \(\cos\varphi\) | Power factor | - |
| \(D/d\) | Outer / inner diameter of the annulus | - |
| \(P\) | Reheating power | W |
| \(A_c\) | Water coil area | m² |
| \(k\) | Mean conductance 6.5(T − 30) µS/cm | - |
| \(L\) | Electric heater active length | m |
Method and standards
Hugot's reheater formulae (Wright's length formula).
Where it is used
- Sizing reheaters.
- Choosing between water and electric reheating.
Common mistakes
- Heating water far above saturation.
- Using hot-water coil area for electric heaters.
Assumptions and limits
- Mean conductance from Hugot's estimate, with T the mean of the inlet and outlet temperatures in °C.
- Wright's length formula is empirical: P in kW, k in µS/cm, V in volts and L in metres; the page converts from SI.
- A note appears for outlet temperatures above 57 °C.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 35
- reheating of massecuite
- eqns 35.52–35.55
- pp. 807–811
Questions and answers
Why reheat?
Cold C massecuite is too viscous to purge; a few degrees halve the viscosity without dissolving much sugar.
How hot?
To about saturation, 50–52 °C; hotter dissolves crystals.
Why electric heaters?
Short time at temperature, simple control and good fit to continuous centrifugals.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.