Massecuite Reheating: Power, Coil and Electric Heater

Heat to reheat low-grade massecuite before curing (Hugot eqns 35.53–35.54), the water coil it needs and the length of an electric-resistance reheater (eqn 35.55).

Sugar mill and cogenerationElectric motor

Inputs

Examples: 8 m3/h C massecuite 40 -> 52Small flow

Hugot: about 50–52 °C, at most 57 °C.
Hugot: 30–35 m² per m³/h with water no more than 3 °C above saturation.

Results

Hugot: viscosity halves for each 5 °C rise; reheating improved a Cuban factory's C sugar purity from 84.7 to 89.4 and cut molasses purity by 1.3 points.

Reheating power70.338kW
Water coil area260.00m²
Mean conductance 6.5(T − 30) µS/cm104.00
Electric heater active length3.8476m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 m3/h C massecuite 40 -> 52. The inputs, in the units selected above:

InputValue
Massecuite flow8.0000 m³/h
Massecuite density1,500.0 kg/m³
Massecuite specific heat1.7585 kJ/(kg·K)
Temperature in40.000 °C
Temperature out52.000 °C
Coil area per m³/h of massecuite32.500 -
Supply voltage400.00 V
Power factor100.00 %
Outer / inner diameter of the annulus1.7674 -

Applying the formula below gives:

ResultValue
Reheating power70.338 kW
Water coil area260.00 m²
Mean conductance 6.5(T − 30) µS/cm104.00
Electric heater active length3.8476 m

Open this example in the calculator and change any input.

Formula

\(P = Q d c (t - t_0), \quad A_c = a_c Q, \quad k = 6.5(T - 30), \quad L = 3.68\times10^6\frac{P\log(D/d)}{kV^2\cos\varphi}\ [P\ \mathrm{kW}]\)

Variables

Symbol Meaning SI unit
\(Q\) Massecuite flow m³/s
\(d\) Massecuite density kg/m³
\(c\) Massecuite specific heat J/(kg·K)
\(t_0\) Temperature in K
\(t\) Temperature out K
\(a_c\) Coil area per m³/h of massecuite -
\(V\) Supply voltage V
\(\cos\varphi\) Power factor -
\(D/d\) Outer / inner diameter of the annulus -
\(P\) Reheating power W
\(A_c\) Water coil area m²
\(k\) Mean conductance 6.5(T − 30) µS/cm -
\(L\) Electric heater active length m

Method and standards

Hugot's reheater formulae (Wright's length formula).

Where it is used

  • Sizing reheaters.
  • Choosing between water and electric reheating.

Common mistakes

  • Heating water far above saturation.
  • Using hot-water coil area for electric heaters.

Assumptions and limits

  • Mean conductance from Hugot's estimate, with T the mean of the inlet and outlet temperatures in °C.
  • Wright's length formula is empirical: P in kW, k in µS/cm, V in volts and L in metres; the page converts from SI.
  • A note appears for outlet temperatures above 57 °C.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 35
  • reheating of massecuite
  • eqns 35.52–35.55
  • pp. 807–811

Questions and answers

Why reheat?

Cold C massecuite is too viscous to purge; a few degrees halve the viscosity without dissolving much sugar.

How hot?

To about saturation, 50–52 °C; hotter dissolves crystals.

Why electric heaters?

Short time at temperature, simple control and good fit to continuous centrifugals.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.