Worked example
Example: C massecuite 70 to 40 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Massecuite flow | 10.000 t/h |
| Massecuite specific heat | 1.9000 kJ/(kg·K) |
| Massecuite in | 70.000 °C |
| Massecuite out | 40.000 °C |
| Cooling-water temperature rise | 8.0000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat removed | 158.33 kW |
| Cooling water | 17.018 t/h |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_m c_p (T_1 - T_2), \quad \dot m_w = \frac{\dot Q}{c_w \Delta T_w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_m\) | Massecuite flow | kg/s |
| \(c_p\) | Massecuite specific heat | J/(kg·K) |
| \(T_1\) | Massecuite in | K |
| \(T_2\) | Massecuite out | K |
| \(\Delta T_w\) | Cooling-water temperature rise | K |
| \(\dot Q\) | Heat removed | W |
| \(\dot m_w\) | Cooling water | kg/s |
Method and standards
Energy balance.
Where it is used
- Crystalliser element sizing.
- Cooling water planning.
Common mistakes
- Heat of crystallisation double counted.
Assumptions and limits
- Steady flow.
- The heat of crystallisation is neglected (it is small against the sensible heat).
- The cooling-water inlet temperature is not an input, so the approach is not checked: the water must enter colder than the massecuite outlet temperature, by a margin that the crystalliser design sets.
References
- Energy balance Q = ṁ c_p ΔT; water c_p 4.1868 kJ/kg K
Questions and answers
Why cool C massecuite?
Solubility falls with temperature, so more sucrose crystallises before centrifuging.
Massecuite specific heat?
About 1.8–2.0 kJ/kg K for low-grade massecuites.
How fast?
Slowly, over many hours, to grow existing crystals instead of new grain.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.