FireCADCalc

Massecuite Crystalliser Cooling Duty and Water

Heat removed to cool massecuite in a crystalliser and the cooling-water flow, from massecuite flow, specific heat, temperatures and water rise.

Sugar mill and cogeneration

Inputs

Examples: C massecuite 70 to 40 °CB massecuite

Results

The heat of crystallisation is small and neglected; cool slowly to avoid false grain.

Heat removed158.33kW
Cooling water17.018t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: C massecuite 70 to 40 °C. The inputs, in the units selected above:

InputValue
Massecuite flow10.000 t/h
Massecuite specific heat1.9000 kJ/(kg·K)
Massecuite in70.000 °C
Massecuite out40.000 °C
Cooling-water temperature rise8.0000 K

Applying the formula below gives:

ResultValue
Heat removed158.33 kW
Cooling water17.018 t/h

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_m c_p (T_1 - T_2), \quad \dot m_w = \frac{\dot Q}{c_w \Delta T_w}\)

Variables

Symbol Meaning SI unit
\(\dot m_m\) Massecuite flow kg/s
\(c_p\) Massecuite specific heat J/(kg·K)
\(T_1\) Massecuite in K
\(T_2\) Massecuite out K
\(\Delta T_w\) Cooling-water temperature rise K
\(\dot Q\) Heat removed W
\(\dot m_w\) Cooling water kg/s

Method and standards

Energy balance.

Where it is used

  • Crystalliser element sizing.
  • Cooling water planning.

Common mistakes

  • Heat of crystallisation double counted.

Assumptions and limits

  • Steady flow.
  • The heat of crystallisation is neglected (it is small against the sensible heat).
  • The cooling-water inlet temperature is not an input, so the approach is not checked: the water must enter colder than the massecuite outlet temperature, by a margin that the crystalliser design sets.

References

  • Energy balance Q = ṁ c_p ΔT; water c_p 4.1868 kJ/kg K

Questions and answers

Why cool C massecuite?

Solubility falls with temperature, so more sucrose crystallises before centrifuging.

Massecuite specific heat?

About 1.8–2.0 kJ/kg K for low-grade massecuites.

How fast?

Slowly, over many hours, to grow existing crystals instead of new grain.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.