Worked example
Example: Hugot example: 25 m3/h A massecuite. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Massecuite flow | 25.000 m³/h |
| Massecuite density | 1,500.0 kg/m³ |
| Massecuite specific heat | 1.6747 kJ/(kg·K) |
| Allowance factor | 1.1500 - |
| Heat-transfer coefficient | 69.780 W/(m²·K) |
| Massecuite in | 70.000 °C |
| Massecuite out | 40.000 °C |
| Water in | 25.000 °C |
| Water out | 50.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat removed | 601.85 kW |
| Cooling surface | 496.25 m² |
| Cooling water | 20,700 kg/h |
| Water per kg massecuite (without allowance) | 0.48000 |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \alpha V d c (T_0 - T), \quad S = \frac{\dot Q}{k\,\Delta T_{lm}}, \quad \Delta T_{lm} = \frac{(T_0 - t) - (T - t_0)}{\ln\frac{T_0 - t}{T - t_0}}, \quad W = \frac{\dot Q}{c_w(t - t_0)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Massecuite flow | m³/s |
| \(d\) | Massecuite density | kg/m³ |
| \(c\) | Massecuite specific heat | J/(kg·K) |
| \(\alpha\) | Allowance factor | - |
| \(k\) | Heat-transfer coefficient | W/(m²·K) |
| \(T_0\) | Massecuite in | K |
| \(T\) | Massecuite out | K |
| \(t_0\) | Water in | K |
| \(t\) | Water out | K |
| \(\dot Q\) | Heat removed | W |
| \(S\) | Cooling surface | m² |
| \(W\) | Cooling water | kg/s |
| \(w\) | Water per kg massecuite (without allowance) | - |
Method and standards
Hugot's counter-current heat balance.
Where it is used
- Designing crystalliser cooling elements.
- Cooling water budgets.
Common mistakes
- Taking V in t/h.
- Water outlet above massecuite inlet.
Assumptions and limits
- Counter-current flow; constant properties.
- The water ratio w excludes the allowance while the water flow W includes it.
- The cooling rate of the massecuite (false grain risk) is not checked.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 34
- water-cooled crystallisers
- eqns 34.15–34.17 and example
- pp. 739–744
Questions and answers
Why the allowance α?
Hugot adds 15–20 % for heat of crystallisation and uneven flow.
Which coefficient?
Much lower for C massecuite, and lower again with scale on the elements.
Counter-current?
Yes: the coldest water meets the coldest massecuite, giving the log-mean difference.