FireCADCalc

Multiple-Effect Evaporator Steam with Vapour Bleeding (Rillieux)

Exhaust steam to an n-effect evaporator and the steam saved by bleeding vapour from the effects, by Rillieux's principles (equal evaporation per kg of steam).

Sugar mill and cogeneration

Inputs

Examples: Quintuple with bleedingQuadruple, no bleedingTriple, first-effect bleed

Results

Rillieux's idealisation: 1 kg of steam or vapour evaporates 1 kg in each effect. Real effects give somewhat less.

Steam with no bleeding (heaters on exhaust)37.500t/h
Exhaust steam with bleeding37.500t/h
Steam saved by bleeding0t/h
Evaporation per kg of steam4.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Quintuple with bleeding. The inputs, in the units selected above:

InputValue
Number of effects5.0000 -
Total evaporation200.00 t/h
Vapour bled from effect 140.000 t/h
Vapour bled from effect 225.000 t/h
Vapour bled from effect 310.000 t/h
Vapour bled from effect 40 t/h

Applying the formula below gives:

ResultValue
Steam with no bleeding (heaters on exhaust)115.00 t/h
Exhaust steam with bleeding91.000 t/h
Steam saved by bleeding24.000 t/h
Evaporation per kg of steam2.1978

Open this example in the calculator and change any input.

Formula

\(S = \frac{E + \sum_i (n - i)\,B_i}{n}, \quad S_0 = \frac{E}{n} + \sum_i B_i, \quad x = \frac{E - \sum_i i\,B_i}{n} \ge 0\)

Variables

Symbol Meaning SI unit
\(n\) Number of effects -
\(E\) Total evaporation kg/s
\(B_1\) Vapour bled from effect 1 kg/s
\(B_2\) Vapour bled from effect 2 kg/s
\(B_3\) Vapour bled from effect 3 kg/s
\(B_4\) Vapour bled from effect 4 kg/s
\(S_0\) Steam with no bleeding (heaters on exhaust) kg/s
\(S\) Exhaust steam with bleeding kg/s
\(\Delta S\) Steam saved by bleeding kg/s
\(E/S\) Evaporation per kg of steam -
\(x\) Vapour to the condenser kg/s

Method and standards

Rillieux's principles.

Where it is used

  • Evaporator and pan steam planning.
  • Steam % cane reduction projects.

Common mistakes

  • Bleeding counted as extra evaporation.
  • Vapour from the last effect to the condenser counted as bled.

Assumptions and limits

  • Equal evaporation per kg; heat losses ignored.
  • The vapour left for the condenser x must not be negative: Σ i B_i may not exceed E.
  • With n = 1 (a single effect) bleeding saves its full weight in steam, as Rillieux's i/n = 1.

References

  • Rillieux's principles of multiple-effect evaporation and vapour bleeding (Hugot, Handbook of Cane Sugar Engineering)

Questions and answers

What does Rillieux's third principle say?

Vapour bled from effect i of n to replace exhaust saves i/n of its weight in steam.

Why bleed from later effects?

The saving grows with the effect number, but the vapour is cooler.

Is the evaporation per kg of steam really n?

Ideally; heat losses, BPE and flash change it a little.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.