Worked example
Example: 1000 m2, 45 mm tubes. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heating surface (inside of tubes) | 1,000.0 m² |
| Tube outside diameter | 45.000 mm |
| Tube wall | 1.5000 mm |
| Tube length | 2.2500 m |
| Tube-plate ratio, outside tube area / plate | 50.000 % |
| Inside tube section / calandria section | 36.000 % |
| Downtake / calandria diameter | 20.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Number of tubes | 3,369.0 |
| Tube pitch | 60.585 mm |
| Calandria diameter | 4.0630 m |
| Downtake diameter | 0.81260 m |
Open this example in the calculator and change any input.
Formula
\(N = \frac{S}{\pi d_i L}, \quad p = \frac{0.952\,d_e}{\sqrt{k_e}}, \quad D = \sqrt{\frac{4}{\pi}\frac{N\pi d_i^2/4}{k}}, \quad d_d = r_d D\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | Heating surface (inside of tubes) | m² |
| \(d_e\) | Tube outside diameter | m |
| \(e\) | Tube wall | m |
| \(L\) | Tube length | m |
| \(k_e\) | Tube-plate ratio, outside tube area / plate | - |
| \(k\) | Inside tube section / calandria section | - |
| \(r_d\) | Downtake / calandria diameter | - |
| \(N\) | Number of tubes | - |
| \(p\) | Tube pitch | m |
| \(D\) | Calandria diameter | m |
| \(d_d\) | Downtake diameter | m |
Method and standards
Hugot's tube-plate relations.
Where it is used
- First layout of evaporator bodies.
- Checking quotations.
Common mistakes
- Using outside diameter with inside-surface figures.
- Too close a pitch to expand tubes.
Assumptions and limits
- Triangular pitch; uniform tube field.
- The pitch (from k_e) and the diameter (from k) come from separate ratios. A note checks that the triangular tube field, N(√3/2)p², fits in the plate outside the downtake, and gives the ligament p − d_e for comparison with Hugot's one third of the diameter.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- construction
- eqns 32.10–32.15
- pp. 504–511
Questions and answers
Inside or outside surface?
Hugot (French practice) counts the inside of the tubes; American practice counts the outside, about 8 % more.
Why ligament about d/3?
Enough metal between holes for expanding the tubes; Hugot's pitch p = 1.35 d for k_e = 0.5.
Why a downtake?
Juice rises in the tubes and returns through the central well, giving circulation.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.