FireCADCalc

Evaporation Rate by Dessin's Formula

Specific evaporation coefficient of an evaporator vessel by Dessin's formula (Hugot eqn 32.31), and its evaporation per m² and in total from surface and drop.

Sugar mill and cogeneration

Inputs

Examples: Hugot check: brix 15, 120 °C, 8.2 °CSyrup effect with scale allowance

Hugot: 0.001 for clean vessels on known juice; 0.0008–0.0009 to allow for scale.

Results

Hugot's check: first vessel, mean brix 15, steam 120 °C, drop 8.2 °C gives c = 5.61 and 46 kg/(m²·h).

Specific evaporation coefficient, kg/(m²·h·°C)5.5440
Evaporation per m²45.461kg/(m²·h)
Evaporation31,823kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot check: brix 15, 120 °C, 8.2 °C. The inputs, in the units selected above:

InputValue
Mean brix in the vessel15.000 %
Heating steam or vapour temperature120.00 °C
True temperature drop (steam to boiling juice)8.2000 K
Heating surface700.00 m²
Dessin factor0.001000 -

Applying the formula below gives:

ResultValue
Specific evaporation coefficient, kg/(m²·h·°C)5.6100
Evaporation per m²46.002 kg/(m²·h)
Evaporation32,201 kg/h

Open this example in the calculator and change any input.

Formula

\(c = f(100 - b)(T - 54) \;[\mathrm{kg/(m^2\,h\,^\circ C)};\ b\ \%;\ T\ ^\circ C], \quad g = c\Delta, \quad E = g S\)

Variables

Symbol Meaning SI unit
\(b\) Mean brix in the vessel -
\(T\) Heating steam or vapour temperature K
\(\Delta\) True temperature drop (steam to boiling juice) K
\(S\) Heating surface m²
\(f\) Dessin factor -
\(c\) Specific evaporation coefficient, kg/(m²·h·°C) -
\(g\) Evaporation per m² kg/(m²·s)
\(E\) Evaporation kg/s

Method and standards

Dessin's formula as given by Hugot.

Where it is used

  • Designing and checking multiple effects.
  • Comparing vessels.

Common mistakes

  • Using the apparent drop between vapour temperatures.
  • Brix as a fraction.

Assumptions and limits

  • Robert (short-tube) vessels.
  • The true drop is entered by you and is not checked against the boiling-point elevation and hydrostatic head; the note gives Hugot's check case only.
  • c is in kg/(m²·h·°C) in every unit system (there is no unit list for it).

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • eqn 32.31 (Dessin) and Table 32.18
  • pp. 576–580

Questions and answers

Why does brix appear?

Thick syrup is viscous and boils sluggishly, so later effects evaporate less per degree.

Why T − 54?

Dessin's fit: the coefficient falls towards zero as the heating temperature approaches about 54 °C.

Which drop?

The true drop: heating steam temperature minus the boiling temperature of the juice, after boiling-point elevation and head.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.