Worked example
Example: First body. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Evaporation in this body | 40.000 t/h |
| Heating steam or vapour pressure (absolute) | 2.0000 bar |
| Body (vapour space) pressure (absolute) | 1.6000 bar |
| Boiling-point elevation | 0.50000 K |
| Overall heat-transfer coefficient | 2,500.0 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Useful temperature difference | 6.4133 K |
| Heat duty | 24,675 kW |
| Heating surface | 1,538.9 m² |
| Heating steam or vapour condensed | 40.348 t/h |
Open this example in the calculator and change any input.
Formula
\(\Delta T = T_{sat}(p_h) - [T_{sat}(p_b) + BPE], \quad \dot Q = E\,h_{fg}(p_b), \quad A = \frac{\dot Q}{U \Delta T}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E\) | Evaporation in this body | kg/s |
| \(p_h\) | Heating steam or vapour pressure (absolute) | Pa |
| \(p_b\) | Body (vapour space) pressure (absolute) | Pa |
| \(BPE\) | Boiling-point elevation | K |
| \(U\) | Overall heat-transfer coefficient | W/(m²·K) |
| \(\Delta T\) | Useful temperature difference | K |
| \(\dot Q\) | Heat duty | W |
| \(A\) | Heating surface | m² |
| \(\dot m_s\) | Heating steam or vapour condensed | kg/s |
Method and standards
Energy balance.
Where it is used
- Evaporator design and debottlenecking.
Common mistakes
- BPE left out in the syrup body.
Assumptions and limits
- Feed at boiling point and no heat loss: for a colder feed, or with losses, more steam is condensed than shown; flash from a hotter feed reduces it.
- For a pan the same balance is used, with no massecuite-specific terms (crystallisation heat, changing level and brix).
References
- Q = U A ΔT with boiling-point elevation; latent heats from IAPWS-IF97
Questions and answers
What is the useful temperature difference?
Heating steam saturation temperature less the boiling temperature of the juice, BPE included.
Which U?
Plant data by body: high in the first body, low in the syrup body.
Hydrostatic head?
It raises the boiling point at the tube bottom; add it to the BPE for tall tubes.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.